Portable power monitor
Hide thumbs Also See for ZN-CTX21:
Table of Contents

Advertisement

Rate/CO
Conversion Value
2
Unit
Upper: Displays the rate/CO
Lower: Shows the unit of the rate/CO
Ranking
Integrated Power
The unit shows the integrated power ranking from the highest to lowest value for
individual intervals specified by the INTEG setting.
The display starts from the 1st rank.
Upper: Displays the ranking.
Lower: Displays the integrated power of the rank displayed at the upper row.
Ranking
Start Date
Continuously displays the ranking information.
Upper: Displays the ranking.
Lower: Alternately displays the integrated power measurement start date and start time
pertaining to the ranking shown at the upper row.
AVE
Ave. Momentary Power
Continuously displays the ranking information.
Upper: Displays the "AVE", "MAX" and "MIN" indications repeatedly.
Lower: Repeatedly shows the average (AVE), maximum (MAX) and minimum (MIN)
integrated power values.
Similarly, the succeeding ranks up to the 9th and their information are
sequentially displayed.
Integrated Power
Threshold Value
Upper: Displays the integrated power from the measurement start.
Lower: Displays the upper limit threshold value.
Integrated Power
Threshold Rate
Upper: Displays the integral power.
Lower: Displays the threshold rate (Integrated Power ÷Threshold).
5. Measurement and Recording (Unit Operation)
conversion value.
2
conversion value.
2
Ranking
Start Time
MAX
Max. Momentary Power
5-3
MIN
Min. Momentary Power