Definition Of Items; Upper Limit Threshold Of Kwh Or Higher Integrated Power (Int H); Upper Limit Threshold Of Less Than Kwh Integrated Power (Int H); Changing The Set Value - Omron ZN-CTX21 User Manual

Portable power monitor
Hide thumbs Also See for ZN-CTX21:
Table of Contents

Advertisement

4.3.4 Definition of Items

(1)

Upper Limit Threshold of kWh or Higher Integrated Power (INT H)

Specifies the integrated power consumption upper limit threshold for an alarm output.
The "ALM" indication and alarm output turn ON, when the measured integrated power
exceeds the set value.
Setting range (Numeric input):
0 Wh to 99999 kWh (Threshold setting becomes "OFF" if "0" is specified)
Initial value:
0 kWh
(2)

Upper Limit Threshold of Less than kWh Integrated Power (INT H)

Specifies the integrated power consumption upper limit threshold for an alarm output.
The "ALM" indication and alarm output turn ON, when the measured integrated power
exceeds the set value.
Setting range (Numeric input):
0 Wh to 999 Wh (Threshold setting becomes "OFF" if "0" is specified)
Initial value:
0 Wh

4.3.5 Changing the Set Value

Follow the same procedure as in FUN mode.
Refer to: 4.2.5 Changing the Set Value
4.4

Copying Setting Data for Multiple Monitor Units

The settings on multiple Portable Power Monitor units can be unified by using the same
setting data saved in an SD memory card. This is convenient especially when controlling
multiple monitor units using the same settings. Make necessary settings only on one unit
(through unit operation), save it in an SD memory card and then, restore it in other units. This
can greatly save the entire setting procedures, thus, minimizing setting errors.
Refer to: 4.2.4 (14) Writing the Setting Data (BCKUP), 4.2.4 (13) Reading Setting Data
(RESTR)
4. Setting the Unit (Unit Operation)
4-25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Equo series

Table of Contents