9. Compensation Level Display
. The Compensation Level menu indicates the compensa-
tion level of the already-registered RPN correction point
when the crosshair cursor is moved to a correction point
by the Cursor Next or Cursor Prev operation, and if the
compensation mode of the already-registered point is
Compensation.
. The Compensation Level menu is dedicated to display
only and the cursor cannot be moved to this menu.
10. Executing Record
. The Record menu enables the manual registration of
RPN.
. When Record menu is selected, the Execute and Cancel
choices appear.
Selecting Execute starts the registration of RPN.
11. Executing Delete
. The Delete menu enables manual deletion of RPN.
. When the Delete menu is executed, the RPN registration
of a pixel at an address specified by the Cursor H
Position and Cursor V Position is deleted from RPN
data.
. When the Delete menu is selected, the Execute and
Cancel choices appear.
Selecting Execute starts deletion of RPN.
12. Readout Mode Setting
. The Readout Mode menu enables the user to select the
Frame readout mode of the imager in order to facilitate
viewing the RPN position on a monitor screen.
. The Readout Mode setting is always set to Field when
the power is turned On.
13. Executing Reset
. The Reset menu enables the user to delete the RPN
correction point data that is registered by Auto Detect
and Auto Black Balance after the equipment is shipped
from the factory.
. The RPN data that is registered at the factory and the
RPN data is manually registered cannot be deleted by the
Reset.
. When the Reset menu is selected, the Execute and
Cancel choices appear.
In addition, selecting Execute starts reset of RPN.
3-8
RPN manual registration procedure
. Set the Video Format to HQ 1080/60i.
. Set the Readout Mode to Frame.
(To facilitate viewing the RPN position on a monitor
screen.)
. Set the lens iris to CLOSE.
. Adjust GAIN and Black Level to the settings that
facilitate viewing the RPN position on a monitor screen.
. Set Channel to the RPN color that is going to be regis-
tered.
. Set Cursor to On.
. Move the crosshair cursor to the RPN that is going to be
registered by using Cursor H Position and Cursor V
Position.
(When the crosshair cursor is moved on top of the
desired RPN, the RPN becomes invisible.)
. Set Correction Mode to Concealment.
. Execute the Record.
* When RPN Record is attempted, if the RPN registration
of a pixel fails at a specific address due to a problem
with the small interval between the current and previous
registered RPN spots, the screen shows the message
"NG : Adjacent Pixel".

3-3-3. INFORMATION Menu

The INFORMATION menu enables operations such as
displaying the information inherent to a specific machine
and executing Self Diag.
1. Displaying the Serial Number
. The serial number of the unit is displayed on the Serial
Number.
. The cursor cannot be moved to the Serial Number.
2. Displaying the Version Number
. The software version of the unit is displayed on the
Version.
. The cursor cannot be moved to the Version.