: Push the ground wire (1) on to
the contact spring (2) as far as
stop.
– Pull the short circuit wire into the
switch shaft and install the switch
shaft, b 12.1.1
: Fit the grommets (arrows) in the
holes and make sure they are
properly seated.
2
: Fit the short circuit wire (1) and
ground wire (2) in the guides
(arrows).
MS 200, MS 200 T
The wires must be pressed firmly
into the guies and fit snugly against
the handle housing.
1
: Press the wiring harness into the
guide (arrow) on the underside of
the housing.
– Install the handle housing,
b 12.4
The impulse hose must be fitted on
the nipple on the handle housing.
1
: Connect the wiring harness (1) to
the short circuit wire (2).
– Push the wiring harness into the
handle housing.
The short circuit and ground wires
must be routed over the annular
buffer to ensure they are not
pinched between the annular buffer
and handle housing.
: Lift the handle housing slightly
and place annular buffer in
position. Fit the ground wire (1)
and insert the screws, b 11.2
– Reassemble all other parts in the
reverse sequence.
– Tightening torques, b 3.5
– Check operation.