11 INSTRUCTIONS AND FUNCTIONS
11 - 283
• Device numbers expressed in sequential addresses are automatically assigned in
ascending order, starting with the device number with the smallest block number
(number 1).
Device No.
0
1
to
8191
8192
8193
to
16383
16384
to
• Device numbers are not assigned to block numbers that do not exist in the memory
cassette.
When the device numbers are assigned, block numbers not found in the memory
cassette are skipped.
Device No.
0
to
block No.1
8191
8192
to
block No.2
16383
16384
to
block No.10
24575
24576
to
block No.11
32767
32768
to
block No.12
See the ACPU Programming Manual (Basics), AnA/AnUCPU User's Manual,
SW GHP-UTLP-FN1 Operating Manual, or SWvSRX-FNUP Operating Manual for an
explanation about the relationships between the memory cassette and block numbers.
(L)
Area of R0
(H)
(L)
Area of R1
(H)
(L)
Area of R8191
(H)
(L)
Area of R0
(H)
(L)
Area of R1
(H)
(L)
Area of R8191
(H)
(L)
Area of R0
(H)
Area of
Area of
In case block No.'s 3 to 9 do not exist due
to the capacity of the memory cassette
Area of
and the usage conditions.
Area of
Area of
MELSEC-Q
Area of
block No.1
Area of
block No.2
Area of
block No.3
11 - 283