Mitsubishi QD51 Programming Manual page 400

Logic controller
Hide thumbs Also See for QD51:
Table of Contents

Advertisement

11 INSTRUCTIONS AND FUNCTIONS
11 - 230
Format 2 control table
%(0)
• • • • • •
Format 2 control table
%(1)
• • • • • •
Specify the network number of the network to be accessed.
See Section 4.2.2 for the allowable specification range.
%(2)
• • • • • •
Specify the station number of the PLC CPU whose type
name is to be read.
See Section 4.2.2 for the allowable specification range.
%(3)
• • • • • •
Detailed error codes are stored here.
See Appendix 4.4.2 for the details about the error codes.
%(4)
• • • • • •
Processing code
%(5)
• • • • • •
Specify the device using the defined code.
%(6)
• • • • • •
Specify the device number (lower digit) of the device
specified in %(5). See Section 4.2.5 for the allowable
specification range.
%(7)
• • • • • •
Specify the device number (higher digit) of the device
specified in %(5). See Section 4.2.5 for the allowable
specification range.
%(8)
• • • • • •
Specify the number of device points to be read, including
the devices specified in %(5), %(6), and %(7).
The allowable specification ranges are as follows:
(a) Bit devices
(b) Word devices
• Specify 256 (&H100).
• Specify 515 (&H203).
• See Section 4.2.5 for the code numbers.
• Q series CPU
• QnA series CPU
• Q series CPU
• QnA series CPU
MELSEC-Q
1 to 15360 points
1 to 7680 points
1 to 960 points
1 to 480 points
11 - 230