Mitsubishi QD51 Programming Manual page 387

Logic controller
Hide thumbs Also See for QD51:
Table of Contents

Advertisement

11 INSTRUCTIONS AND FUNCTIONS
11 - 217
Format 2 control table
%(0)
• • • • • •
Format 2 control table
%(1)
• • • • • •
Specify the number of the network to be accessed.
See Section 4.2.2 for the allowable specification range.
%(2)
• • • • • •
Specify the station number of the PLC CPU from which
data is to be read.
See Section 4.2.2 for the allowable specification range.
%(3)
• • • • • •
Detailed error codes are stored here.
See Appendix 4.4.2 for the details about the error codes.
%(4)
• • • • • •
Processing code
%(5)
• • • • • •
Specify the starting address of the parameter area to be
read.
%(6)
• • •
%(7)
• • • • • •
Specify the number of bytes to be read.
• Specify 256.
• Specify 14.
MELSEC-Q
11 - 217

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ad51h-s3Qd51-r24A1sd51s

Table of Contents