Strata CT Installation
LED Status Indications
Table 2-19
LED
PWR
SD
RDER
SYCF
H
SYCS
RST
C
Monitor Port Communication Parameters
Data rate:
Data word bits:
Parity:
Stop bits:
Monitor Port Pin Assignments
1: RD
2: TD
3: DSR
4: DTR
5: DCD
6: SG
2-56
Blinking: Power is supplied
Off: Power is not supplied
On: Optical signal not detected
Off: Optical signal detected
On: Code rule violation detected in received data
Off: Code rule violation not detected in received data
On: Frame synchronisation of received data not established
Off: Frame synchronisation of received data established
On: System synchronisation between cabinets not established
Off: System synchronisation between cabinets established
On: Reset signal from CTU detected
Off: Reset signal from CTU not detected
9600 bps
8
None
1
Function
Strata CT I&M Manual October 2000
Normal
Condition
Blinking
Off
Off
Off
Off
Off