MDFB Wall Mounting

H
Figure 5-15
C
MDFB Volume Control Adjustments

Door Phone/Lock Programming

Strata CT I&M Manual October 2000
Two Wall
Mounting Holes
Door Phone (MDFB) Installation
1.
Remove the screw from the bottom of the cover. Detach the cover from the base and
metal frame (see
Figure
2.
Position the metal frame and base to the mounting surface and secure with two one-inch
panhead wood screws.
3.
Attach cover to the metal frame and base and secure with the screw which was removed
in Step 1.
1.
Remove the screw from the bottom of the MDFB cover.
2.
Detach the cover from the base and metal frame.
3.
The volume level is changed by a screw adjustment on the back of the MDFB. Turn the
screw with a flat-headed screwdriver while ringing the MDFB or while on a call with it.
The volume level will change as the screw is turned.
Program 39: Assigns door phone and door lock buttons to digital telephones.
Program 77-1: Assigns DDCBs or HDCB to ports, door phone ringing over external page
during the NIGHT mode, and door lock activation time.
Program 77-2: Busy out unused MDFB positions, identifies which DDCBs support the door
lock option, and sets the door phone to ring one or five times.