Toshiba strata CT Installation & Maintenance Manual page 35

Digital business telephone system
Hide thumbs Also See for strata CT:
Table of Contents

Advertisement

Table 1-17
Option
BPSU672
PBTC-3M
BBDB
H
BFIF
C
Strata CT I&M Manual October 2000
Power Cabinet Hardware
Strata CT cabinet power supply. This power supply can operate with 240VAC connected
as the system's primary AC power source. The power supply is included with each
cabinet ordered but must be installed in the field.
Standard 2 METRE. AC power cords with 240VAC plugs are provided with Strata CT
Base or Expansion cabinets.
A three-meter long battery cable is used to connect reserve power batteries to the
system power supply when the system has less than three cabinets. One reserve power
cable is required for each cabinet in a one or two cabinet system (wall or floor mount).
The cable connects the Strata CT cabinet power supply directly to the battery terminals
(a BBDB is not required).
Strata CT reserve power battery distribution box is required when connecting reserve
power batteries to three or more cabinets (wall or floor mount). The box is field installed
into one of the Strata CT cabinet side panels.
The BBDB provides five BBTC2A-2.0M, battery distribution cables to connect reserve
power from the BDDB box to each individual cabinet power supply.
Also supplied are two BBTC1A-2.0M cables to connect to the BBDB.
Floor mount fixture kit is required when floor mounting Strata CT cabinets.
Provides two metal stands for mounting any number of Strata CT cabinets on the floor.
Three pairs or wall brackets (RWBF) are supplied with BFIF to use when mounting three
or more Strata CT cabinets on floor. The wall brackets are needed to secure floor-
mounted systems to the wall for safety purposes.