Universal Slot PCBs

External Options

W1 Ring Generator Switch Configuration (PSTU2)
Standard Telephone Message Waiting Lamp Control
No steps required here.
Note

RSTU2/RSTU3 Installation

1.
H
2.
3.
C
RSTU2/RSTU3 Controls, Indicators, and Connectors
Table 3-10
Control/Indicator/Connector
Ring voltage W1 jumper
(PSTU1 (V.4) and PSTU2 only)
R48S connector P6
(RSTU or RSTU2 only)
R48S connector P7
(RSTU or RSTU2 only)
3-36
On the PSTU, ensure the W1 switch is set to the "H" (190V P-P) position for initial
installation. The "L" (130V P-P) position is used if devices connected to the PSTU2
experience ring trip.
Only the RSTU3 will support this feature.
Make sure the factory-installed SSTS or SSTU subunit is securely attached to the
PSTU/RSTU
(Figure 3-17
WARNING!
The shield on the back of the RSTU is designed to protect
the installer from potentially hazardous ring voltage. Do
NOT remove this shield.
Insert the PSTU/RSTU3 (component side facing right) into the appropriate slot, and
apply firm, even pressure to ensure proper mating of connectors.
After installing the PSTU/RSTU, gently pull the PSTU/RSTU outward. If the
connectors are properly mated, a light resistance is felt.
Type of Component
3-terminal jumper
9-pin connector
6-pin connector
and
Figure
3-18).
Sets ring generator voltage level for
all circuits. H=190V P-P, L=130V P-P .
Interface connector to P6 of R48S.
Interface connector to P7 of R48S.
Strata CT I&M Manual October 2000
Description