Fault Finding
Flowchart 8-5
START
DSS
console
type?
HDSS
On PEKU connected
to HDSS, set SW1
to the DSS position.
Go to
5-0
H
C
8-12
DSS Console Faults
Is the correct
DDSS
PCB slot code entered
5-0
in Program 03?
Refer to Chapters 4 and verify wiring:
For DDSS, circuit 8 of the base
unit or PDKU.
For HDSS, circuit 7 and 8 of
PEKU (PESU does not support
HDSS).
Correct as necessary.
Is the
fault
cleared?
Test DSS cable with cable continuity
checks in this chapter.
Correct as necessary.
Is the
fault
cleared?
Call your technical
support group.
No
5-1
Yes
5-3
5-4
Yes
END
No
5-5
Yes
END
No
1883 CT I&M
Strata CT I&M Manual October 2000
Enter correct PCB slot
code using Program 03;
then turn power OFF
(for 5 seconds) and
then ON.
5-2
Is the
No
Go to
fault
cleared?
Yes
END