13. Fill out the slot identification label on the cabinet (see
14. Reinstall the front cover, top cover, and side covers onto the cabinet.

Wall Mounting Expansion Cabinets

1.
Note
2.
3.
4.
H
5.
6.
C
7.
Important!
8.
9.
10. Reinstall covers onto cabinets.
2-10
Remove the front, back, and side covers from the Expansion Cabinets.
The two screws on the front cover and the two screws on each side cover should be
loosened just enough to slide the covers off. The front cover slides left and the side
covers swing out and down for removal.
Hold an Expansion Cabinet back cover against the wall so that its top locating parts
align with the bottom locating parts of the Base Cabinet back cover (see
Page
2-11). To secure the Expansion Cabinet back cover to the back board, repeat Steps
5~11 from
"Wall Mounting the Base (Top) Cabinet" on Page
To install additional Expansion Cabinet back covers, repeat Step 2 above.
Starting with the top Expansion Cabinet back cover (which is fastened to the wall),
position an Expansion Cabinet on the back cover cabinet hangers. Slide the cabinet to
the right to the proper mounting position, and secure the cabinet to the back cover with
two screws to the right side of the back cover. Repeat for all other Expansion Cabinets.
Loosen the bonding connection plates fastened on both sides of the first Expansion
Cabinet (see
Figure
2-8) then fasten the plates between the Base Cabinet and the first
Expansion Cabinet. Repeat to connect the first Expansion Cabinet to the second
Expansion Cabinet, etc.
Base Cabinet: Loosen data cable door locking screws and open data cable doors; then
connect the first Expansion Cabinet data cable to the "CAB 2" (top) data cable
connector on the Base Cabinet. Install data cables in appropriate connectors for all other
Expansion Cabinets. (See
After all data cables are installed, close data cable doors and secure with the locking
screw.
Data cable door screws must be firmly tightened for proper system operation.
Data cables for DK280 cabinets are not compatible with Strata CT cabinets.
Install ground wiring, AC and reserve power cabling, and PCB cabling per the
"Recommended Installation Sequence" on Page
Fill out cabinet/slot identification labels on each cabinet.
Figures 2-8
and 2-11.
2-5.