Heater Engine Installation; Masonry Installation - Rinnai 650 Operation & Installation Manual

Hide thumbs Also See for 650:
Table of Contents

Advertisement

MASONRY INSTALLATION

Read this manual thoroughly and gain a full understanding of the requirements before
undertaking installation.
IMPORTANT
Ensure gas supply to heater is turned off for the first stages of this instruction.
Step 1.
Prepare Site - p.30
Step 2.
Masonry Flue Installation - p.30
Step 3.
Masonry Flue Installation - p.30
Step 4.
Positioning The Heater Engine - p.31
Step 5.
Connect Electrical Supply - p.31
Step 6.
Prepare Gas Supply - p.31
Step 1. Prepare Site
Ensure the intended enclosure meets the requirements of the dimensions as stipulated in
"ENCLOSURE REQUIREMENTS" on page 22 and that gas and electrical supplies have been
IMPORTANT
prepared in accordance with the dimensions stipulated in "GAS SUPPLY" on page 24 and
"ELECTRICAL SUPPLY" on page 25.
In a masonry fireplace use a slurry of sand and cement to level the base as required.
Step 2. Unpack The Heater Engine
The heater engine is supplied in one carton, check to ensure you have all
contents as listed under "BEFORE YOU START" on page 4 at the start of
this manual before proceeding. Carefully remove carton by removing the
straps and lifting the carton off the appliance. Remove all packaging
materials and check all components for damage. If ANY damage is evident
DO NOT install or operate this appliance. Contact your supplier for advice.
Step 3. Masonry Flue Installation
Connect both the Ø 100mm exhaust pipe
and the Ø 75mm inlet pipe
A
the masonry cowl
/ co-linear to coaxial
C1
adaptor
, noting that the larger
C2
diameter pipe is for the exhaust, securing
both pipes to the cowl / co-linear to coaxial
adaptor firmly with pipe clamps
Feed the flexi-liner flue pipes down the
chimney ensuring that exhaust pipe
on the right when being viewed from the
front of the fireplace. Once the pipe ends
are accessible from fire place, the cowl /
co-linear to coaxial adaptor components
may then be secured and weather sealed
in place.
At the fire place attach both exhaust pipe
and inlet pipe
A
B
spigot plate
, noting again that the larger
E
diameter pipe is for the exhaust, when
viewed from the front this will be to the
right. Secure both pipes to the spigot plate
firmly with pipe clamps
E
A horizontal masonry installation MUST use a horizontal masonry terminal mount to affix the co-
linear adaptor and the horizontal wall terminal to the exterior wall.
IMPORTANT
Rinnai

HEATER ENGINE INSTALLATION

flues to
B
.
D
D
B
is
A
A
flues to the engines
.
F
Step 7.
Insert Heater Engine Into Fireplace - p.31
Step 8.
Securing The Heater Engine - p.31
Step 9.
CONNECTING THE GAS SUPPLY - p.35
Step 10. LEAK TESTING - p.35
Step 11. BURNER MEDIA INSTALLATION - p.36
Step 12. COMMISSIONING INSTRUCTIONS - p.39
F
30
Retain
carton for use in the
HINT
"Positioning The Heater
Engine" on page 31.
C1
C1
A
B
A
the of heater engine
B
E
E
the
cardboard
C2
From the top
DV 600_700 OIM
R

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

750Rdv600erRdv700er600

Table of Contents