Rinnai 650 Operation & Installation Manual page 41

Hide thumbs Also See for 650:
Table of Contents

Advertisement

4. Press the 'UP' button
the table below.
Model
P L (stage 1)
P H (stage 7)
Refer to chart for the correct gas settings, (data plate values override values printed in this instruction).
5. Press the 'Set Button'
stage 7).
6. Press the 'UP' button
or when the desired pressure is achieved press the 'Set Button'
7. The display
, will now show
13
and the pressure setting procedure should be repeated from step 1 onward after turning the appliance 'OFF'
8. With the display
13
9. Setting main burner pressure is now complete. Remove the manometer hose and replace the inlet test point
screw
. Check for leaks using soapy water solution.
1
Step 3 . Checking and setting Pilot burner pressure.
1. Remove the pilot flame gas test point screw
2. Press the heater ON/OFF button
3. Press the 'TEST' button
its lowest setting, (Main burner - stage 1), and the display
Pilot Flame Pressure
Refer to chart for the correct gas settings, (data plate values override values printed in this instruction).
4. Adjust the pilot flame gas pressure to the value for the gas type as listed in the table below via the 'Pilot Flame
Pressure Adjustment' screw
5. Press the heater ON/OFF button
and replace the pilot flame gas test point crew
6. Check for gas leaks using soapy water, setting or checking pilot burner pressure is now complete.
The Requirements of AS / NZS 5601 include:
a. checking whether mechanical extraction ventilation draws air through flue systems or
NOTE
chimneys or not. If yes, this will most likely result in combustion product spillage from
appliances during their operation.
b. checking whether the operation of appliances and flue systems or chimneys is satisfactory.
c. a method for determining the additional fixed ventilation area required to counteract the
effect of mechanical extract ventilation.
Always check gas pressure values to those recorded on this appliances data plate, values on the
data plate override values printed in this instruction.
WARNING
Rinnai
COMMISSIONING INSTRUCTIONS
or 'DOWN' button
8
RDV600ER
0.20 kPa
0.90 kPa
, once to save the setting. The display
11
or 'DOWN' button
8
. If the display does not change to
, showing
Press the heater ON/OFF button
to start the ignition sequence, the appliance will ignite normally.
12
, twice on the PCB control panel, the igniter will spark and the appliance will light to
6
.
3
, once to stop the appliance operation. Disconnect the manometer hose
12
to adjust to the required value if values are different to those in
9
Natural Gas
RDV700ER
0.20 kPa
0.86 kPa
, should now be displaying
13
to adjust to the required value, If the pressure is already correct
9
, once to save the setting.
11
, and connect a positive pressure manometer hose.
2
, will show
13
Natural Gas
1.00 kPa
.
2
41
Propane Gas
RDV600ER
0.50 kPa
1.95 kPa
there was an error in pressure setting
.
12
.
Propane Gas
2.00 kPa
RDV700ER
0.50 kPa
1.92 kPa
, (Main burner
V 600_700 OIM
RD