Timing Clock; Bulk Dump; System Exclusive Message - Yamaha CL5 Reference Manual

Digital
Hide thumbs Also See for CL5:
Table of Contents

Advertisement

2 SYSTEM REALTIME MESSAGE
2.1 SONG SELECT
Reception
Select the track number shown in the TITLE LIST screen of the USB memory
recorder.
STATUS
11110011 F3
Song select
Song number 0sssssss ss
Song number (0-127)

2.2 TIMING CLOCK

Reception
This message is used to control effects. This message is transmitted twenty-four
times per quarter note.
Echoing of this message depends on the OTHER item in the ECHO settings.
STATUS
11111000 F8
Timing clock
2.3 ACTIVE SENSING
Reception
Once this message has been received, MIDI communication will be initialized
(e.g., Running Status will be cleared) if no message is received for an interval of
400 ms.
This message is not subject to echoing.
STATUS
11111110 FE
Active sensing
2.4 SYSTEM RESET
Reception
When this message is received, MIDI communication will be initialized (e.g.,
Running Status will be cleared).
This message is not subject to echoing.
STATUS
11111111 FF
System reset

3 SYSTEM EXCLUSIVE MESSAGE

3.1 MMC
< MMC STOP >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message and stops.
STATUS
11110000 F0
System exclusive message
ID No.
01111111 7F
Real time System exclusive
Device ID
0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND
00000110 06
Machine Control Command(MCC) sub-id
00000001 01
Stop(MCS)
EOX
11110111 F7
End of exclusive
< MMC PLAY >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message and starts playback.
STATUS
11110000 F0
System exclusive message
ID No.
01111111 7F
Real time System exclusive
Device ID
0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND
00000110 06
Machine Control Command(MCC) sub-id
00000010 02
Play(MCS)
EOX
11110111 F7
End of exclusive
(F3)
< MMC DEFERED PLAY >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message and starts playback.
STATUS
11110000 F0
System exclusive message
ID No.
01111111 7F
Real time System exclusive
Device ID
0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND
00000110 06
Machine Control Command(MCC) sub-id
(F8)
00000011 03
Deferred Play(MCS)
EOX
11110111 F7
End of exclusive
< MMC RECORD STROBE >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message, and if stopped, starts
recording.
STATUS
11110000 F0
System exclusive message
(FE)
ID No.
01111111 7F
Real time System exclusive
Device ID
0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND
00000110 06
Machine Control Command(MCC) sub-id
00000110 06
Record strobe
EOX
11110111 F7
End of exclusive
< MMC PAUSE >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message, and if playing, pauses.
(FF)
STATUS
11110000 F0
System exclusive message
ID No.
01111111 7F
Real time System exclusive
Device ID
0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND
00000110 06
Machine Control Command(MCC) sub-id
00001001 09
Pause(MCS)
EOX
11110111 F7
End of exclusive

3.2 BULK DUMP

This message is used to send or receive the contents of various memories stored
within the unit.
The basic format is as follows.
Command
F0 43 0n 3E cc cc 19 mm ... mm dd
dd ... ee F7
F0 43 2n 3E 19 mm ... mm dd dd F7
The CL series console uses the following data types for a bulk dump.
Module Name(mm)
SCENE LIB
"SCENE
INPUT EQ LIB
"INEQ
OUTPUT EQ LIB
"OUTEQ
Dynamics LIB
"DYNA
INPUT CH LIB
"INCHNNL_"
OUTPUT CH LIB
"OUTCHNNL"
GEQ LIB
"GEQ_
8BandPEQ LIB
"8PEQ
EFFECT LIB
"EFFECT "
Premium Effect
"PEFFECT_"
Portico5033 LIB
"P5033_ "
37
Module Name(mm)
Portico5043 LIB
U76 LIB
Opt-2A LIB
EQP-1A LIB
DynamicEQ LIB
Buss Comp 369 LIB
Dante Input Patch LIB
Mixer Setup
Outport Setup
Monitor Setup
MIDI Setup
Lib Number
Program Change Table
Control Change Table
Preference (Current)
Preference (Admin)
Preference (Guest)
User Defined Keys (Current)
User Defined Keys (Admin)
User Defined Keys (Guest)
Custom Fader Bank (Current)
Custom Fader Bank (Admin)
Custom Fader Bank (Guest)
User Level (Current)
User Level (Guest)
*1) 0-300 Scene Number (0 Request Only),
*2) 1-199 Input EQ Library Number (1-40 Request Only)
*3) 1-199 Output EQ Library Number (1-3 Request Only)
*4) 1-199 Dynamics Library Number (1-41 Request Only)
*5) 0-199 GEQ Library Number (0 Request Only)
*6) 1-199 Effect Library Number (1-27 Request Only)
*7) 512-583 Input 1-72,
*8) 584-599 STIN 1L-8R,
*9) 768-791 MIX 1-24,
*10) 1024-1031 MATRIX 1-8,
*11) 1280-1282 STEREO L-C,
*12) 512-530 GEQ 1-19, 531-538 EFFECT GEQ 1-8,
*13) 0-199 8BandPEQ Library Number (0 Request Only)
*14) 512-519 EFFECT 1-8,
*15) 512 Current Data,
*16) 768 Current Data with Recall Safe,
rx/tx
Function
*17) 8192 Store Undo Data, 8193 Recall Undo Data, 8194 Clear Undo Data,
rx/tx
BULK DUMP DATA
*18) 0-199 Input CH Library Number (0 Request Only),
*19) 0-199 Output CH Library Number (0 Request Only),
*20) 512-527 Premium Rack 1A, 1B, 2A, ... 8A, 8B
rx
BULK DUMP REQUEST
*21) 0-100 Each Premium Effect Library Number (0 Request Only)
*22) 1536-1607 Input 1-72 (for Dynamics2),
*23) 1608-1623 STIN 1L-8R (for Dynamics2),
*24) 0-10 Dante Input Patch Library Number (0 Request Only)
Data Number(dd)
"
*1) *15) *16) *17)
Data is lost when you write to the preset library.
"
*2) *7) *8)
The unique header (Model ID) identifies whether the device is a CL series.
To calculate the check sum, add the bytes starting with the byte after BYTE
"
*3) *9) *10) *11)
COUNT (LOW) and ending with the byte before CHECK SUM, take the binary
"
*4) *7) *8) *9) *10) *11) *22) *23)
complement, and set bit 7 to 0.
*18) *7) *8)
CHECK SUM = (-sum)&0x7F
*19) *9) *10) *11)
Bulk Dumps can be received at any time, and can be transmitted at any time
"
*5) *12)
when a Bulk Dump Request is received.
"
*13)
A Bulk Dump is transmitted on the [Rx CH] channel in response to a Bulk Dump
*6) *14)
Request.
In the data portion, seven words of 8-bit data are converted into eight words of
*20)
7-bit data.
*21)
Data Number(dd)
"P5043
"
*21)
"U76
"
*21)
"OPT-2A "
*21)
"EQ-1A
"
*21)
"DYNAEQ "
*21)
"BSCMP369"
*21)
"DANTEIN_"
*24)
"MIXERSET"
Fix (512)
"OUT_PORT"
Fix (512)
"MONITOR_"
Fix (512)
"MIDI_SET"
Fix (512)
"LIB_NUM_"
Fix (512)
"PRGMCHG_"
Fix (512)
"CTRLCHG_"
Fix (512)
"PREF_CUR"
Fix (512)
"PREF_ADM"
Fix (512)
"PREF_GST"
Fix (512)
"UDEF_CUR"
Fix (512) include Knob, Encoder
"UDEF_ADM"
Fix (512) include Knob, Encoder
"UDEF_GST"
Fix (512) include Knob, Encoder
"CFAD_CUR"
Fix (512)
"CFAD_ADM"
Fix (512)
"CFAD_GST"
Fix (512)
"UKEY_CUR"
Fix (512)
"UKEY_GST"
Fix (512)
Data List

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl1Cl3

Table of Contents