Yamaha CL5 Reference Manual page 243

Digital
Hide thumbs Also See for CL5:
Table of Contents

Advertisement

3
GPI OUT SETUP button
The button shows the name of the currently-selected function or parameter. Press this
button to display the GPI OUT SETUP
You can assign the following functions.
Function
PARAMETER 1
NO ASSIGN
-
-
CUE ACTIVE
CUE ON
-
DCA ONLY
-
INPUT ONLY
-
OUTPUT ONLY
-
DANTE
REDUNDANCY
PRIMARY
IND.
SECONDARY
GPI IN ACTIVE
SPECIFIC PORT PORT 1 to PORT 5
IND.
POWER ON
-
-
SPECIFIC
USER DEF.
USER DEFINED
KEY ACTIVE
NUMBER
KEY 1 to USER
IND.
DEFINED KEY 16
4
TEST button
While this is on, the corresponding GPI OUT port will be active and will output a control
signal.
window.
PARAMETER 2
Description
No assignment
Turn on the [CUE] key of the
selected channel
Turn on the DCA [CUE] key
Turn on the [CUE] key of an input
channel
Turn on the [CUE] key of an output
channel
This function activates when the
unit is operating on the primary
Dante audio network with a star
connection (redundancy network).
This function activates when the
unit is operating on the secondary
Dante audio network with a star
connection (redundancy network).
The function assigned to GPI IN
port 1 - 5 becomes active
The power of the CL series
console is turned on
The function assigned to the
USER DEFINED key becomes
active
Using FADER START
Make FADER START settings if you want a device connected to a GPI OUT port to operate
in tandem with fader operations.
STEP
1. Connect an external device to the CL series console's GPI connector.
2. In the Function Access Area, press the SETUP button.
3. In the SETUP screen, press the MIDI/GPI button.
4. In the MIDI/GPI screen, press the FADER START tab.
5. For each GPI OUT port, specify the channel that will cause the external device to
operate, and the type of operation.
SETUP screen
240
Setup
MIDI/GPI screen
Reference Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl1Cl3

Table of Contents