Reference: LG Pro:Centric Patient Remote and Pillow Speaker
LG Pro:Centric patient remotes and/or pillow speakers are available
for purchase (see patient remote example at right and pillow speaker
example on following page). For additional information and/or to purchase
an LG Pro:Centric patient remote or pillow speaker, please contact your
LG service representative.
Patient Remote and Pillow Speaker Functionality
Both the LG Pro:Centric patient remote and the LG Pro:Centric pillow
speaker provide access to Pro:Centric application features (via PORTAL,
INFO, and GUIDE buttons). See also "Installer Remote Control Typical
Key Functions" on the previous page for further information on button
functions. The patient remote also provides multi-code capability as
described below.
Programming the Patient Remote (Multi-IR Code
Feature)
This section describes how to program the LG Pro:Centric patient
remote to send unique IR codes based on "bed number" in a multi-TV
single room installation. Up to nine beds can be programmed.
Note: The TV will always respond to the standard LG Installer Remote
IR code scheme, regardless of its multi-code IR setting.
The following procedure describes how to program the bed number in
the TV's Installer Menu and in the patient remote.
1. Installer Menu item 020 FEATURE LEVEL determines the additional
IR code scheme to which the TV will respond. Access the Installer
Menu, and set item 020 to the desired value.
The patient remote must now be programmed to match the FEATURE
LEVEL setting. That is, if item 020 is set to 17 for Bed 2, the patient
remote must also be set to Bed 2.
Note: In its default state, the patient remote uses the standard LG
Installer Remote IR code scheme.
2. On the patient remote, press and hold OK along with the desired
(bed) number key.
The LED at the top left of the remote will light for three seconds and
then turn OFF.
3. Once the LED turns OFF, release both keys on the remote.
4. Verify the remote functionality, based on your settings.
Note: If necessary, you can restore the default patient remote IR code
scheme by pressing and holding OK on the remote along with the "0" key.
94
POWER
INPUT
MUTE
CC
VOL +
CH +
OK
VOL -
CH -
PORTAL
INFO
GUIDE
FLASHBK
SAP
EXIT
ALARM
TIMER
Typical LG
Pro:Centric Patient
Remote
206-4292 Draft A.2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

32lx770m55lx770m

Table of Contents