LG 43LX770M Commercial Mode Setup Manual page 38

Hospital grade interactive tvs
Hide thumbs Also See for 43LX770M:
Table of Contents

Advertisement

Installer Menu (Cont.)
Installer Menu Items 000 through 046
Item
Function
000
INSTALLER SEQ
001
POWER MANAGE
002
AC ON
003
BAND/AFC
004
STRT CHANNEL
005
CHAN LOCK
007
STRT VOLUME
008
MIN VOLUME
009
MAX VOLUME
010
MUTE DISABLE
011
KEY DEFEAT
012
IR BANKS EN.
013
SCAN MODE
014
STRT CH IN SM
015
SLEEP TIMER
016
EN. TIMER
017
ALARM
020
FEATURE LEVEL
021
V-CHIP
022
MAX BLK HRS
023
CAPTION LOCK
025
FUNCTION PRE.
027
HOSPITAL MODE
028
CH. OVERIDE
029
OLD OCV
030
ACK MASK
031
POLL RATE
032
TIMING PULSE
035
HDMI1 ENABLE
039
REAR AUX EN.
041
SIMPLINK EN
042
AUTO INPUTS
046
STRT AUX SRCE
38
Value Range
Default Value
0 ~ 3
0
0 ~ 7
0
0 ~ 3
0
0 ~ 3
1
0 ~ 127, 253,
255
255
0 / 1
0
0 ~ 63, 255
255
0 ~ 63
0
0 ~ 63
63
0 / 1
0
0 / 1
1
0 / 1
0
0 / 1
1
0 / 1
0
0 / 1
1
0 / 1
1
0 / 1
1
0 ~ 1, 16 ~ 24,
1
64 ~ 65
0 / 1
1
0 ~ 99
12
0 / 1
0
0 / 1
1
0 ~ 162, 254
254
0 / 1
1
0 / 1
0
0 / 1
0
20 ~ 169
94
186 ~ 227
207
0 ~ 2
1
0 / 1
1
0 / 1
0
0 ~ 255
0
1, 3, 5, 255
255
Brief Description of Function
Leave default set to 0.
Selects the number of hours of inactivity allowed before the TV automatically
turns itself OFF. Set to 0 to disable Power Management.
Set to 1 to enable TV to turn ON when AC power is applied. Set to 2 or 3 to
enable Instant ON when AC power is applied. (See detailed descriptions.)
Selects Tuning Band: 0=Broadcast, 1=CATV, 2=HRC, 3=IRC
Channel tuned when TV is turned ON. (Set to 255 to tune to channel
tuned before TV turned OFF.)
If set to 1, cannot tune from current channel.
Volume level when TV is turned ON. (Set to 255 to use volume level
before TV turned OFF.)
Sets minimum allowable volume setting.
Sets maximum allowable volume setting.
Set to 1 to disable Mute Function.
If set to 1, joystick button menu navigation functions (with the exception of the
input list) on display panel are not available.
Set to 1 to enable TV to respond to bank discrete IR codes.
Set to 1 to allow Channel Up/Down to turn ON TV. (See detailed descriptions.)
Set to 1 to use the Start Channel for the Channel Map pivot point in Scan Mode.
Set to 1 to enable Sleep Timer.
Set to 1 to enable On/Off Timers.
Set to 1 to enable Alarm.
Determines an additional IR code scheme to which the TV will respond.
Set to 1 to enable V-Chip (Parental Control) functions.
Sets number of V-Chip blocking hours.
Set to 1 to retain caption setting set before TV turned OFF.
Set to 1 to allow Channel Preview/Banks Setup Menu access via CH
PREVIEW key on Installer Remote.
Set according to the speaker selection, the pillow speaker code/supply voltage,
and the hospital IR code. See detailed instructions.
If set to 0, user access to channel settings in the TV setup menus is restricted
and users can only tune to channels that are included in the channel lineup.
Set to 1 to remap the PTC's direct tune channels for Aux inputs from 13x to 9x.
If set to 1, enables ACK feature of MPI.
Selects poll rate for MPI.
Sets baud rate for MPI.
Set to 0 to disable HDMI 1. Set to 1 (DTV Mode) or 2 (PC Mode), as
applicable, to enable HDMI 1.
Set to 1 to enable display panel AV input jack.
Determines the status of the SIMPLINK feature. (See detailed descriptions.)
Determines the Aux inputs for which auto-sensing is enabled. (See detailed
Sets the starting Aux source (if item 004 STRT CHANNEL is set to 0).
descriptions.)
206-4292 Draft A.2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

32lx770m55lx770m

Table of Contents