Specifications; Environmental Specifications - Fluke AIRCHECK User Manual

Wi-fi tester
Hide thumbs Also See for AIRCHECK:
Table of Contents

Advertisement

Specifications

Environmental Specifications

Operating temperature and relative
humidity
Operating relative humidity
(% RH without condensation)
Storage temperature
Shock and vibration
Safety
Altitude
EMC
South Korean EMC Standards
Electromagnetic Compatibility.
Applies to use in Korea only. Class A
Equipment (Industrial Broadcasting &
Communications Equipment) [1]
32ºF to 113ºF (0ºC to +45ºC)
The battery will not charge if the internal temperature of the tester is
above 113
F (45ºC).
º
90% (50ºF to 95ºF; 10ºC to 35ºC)
75% (95ºF to 113ºF; 35ºC to 45ºC)
-4ºF to 140ºF (-20ºC to +60ºC)
Random, 2 g, 5 Hz-500 Hz (Class 2) 1 m drop test
IEC 61010-1: CAT none, Pollution degree 2
4,000 m; Storage: 12,000 m
FCC Part 15 Class A, IEC 61326-1: Portable, South Korean Standards
Conforms to relevant South Korean EMC Standards.
[1] This product meets requirements for industrial (Class A) electromagnetic wave
equipment and the seller or user should take notice of it. This equipment is
intended for use in business environments and is not to be used in homes.