CompoWay/F Message Communications
Write Basic Settings
Write Timer Setting
Write Hysteresis Width
88
The data contents are shown in the following table.
Bit
00
Display Contents:
0: Digital incident level
01
1: Digital percentage
2: Analog incident level
02
Display Orientation:
0: Standard
1: Reversed
03
Hold Setting:
0: OFF
04
2: Peak
3: Bottom
05
Flashing Setting:
0: OFF
1: ON
06
Sensing Setting:
0: Standard
07
2: Long-distance
3: High-speed
08
Timer Mode:
09
1: OFF-delay
2: ON-delay
3: One-shot
10
Number of Display Digits:
11
0: 4 digits
1: 3 digits
12
2: 2 digits
3: 1 digit
4: 0 digits
13
Always 0.
14
Teaching during RUN
0: OFF
1: ON
15
Eco Mode
0: OFF
1: ON
Writes the timer setting for the OFF-delay, ON-delay, or one-shot timer as a 4-
digit hexadecimal value. The setting range is "0000" to "00C8" (0 to 200 ms),
but the possible settings are restricted as follows:
Timer setting
0 to 20 ms
1-ms increments
20 to 200 ms
5-ms increments
An error will occur if a write operation is executed using a setting interval that
does not meet the restrictions.
Writes the hysteresis width as a 4-digit hexadecimal value.
Contents
Setting interval
Section 4-5