Overview of DeviceNet Communications Model
Transferring, Monitoring,
and Operating from the
DeviceNet Configurator
CS/CJ-series DeviceNet Unit
E3X-DRT21 Fiber
Amplifier Sensor
Communication Unit
for DeviceNet
14
A DeviceNet Configurator (Ver. 2.10 or higher) can be used to read and write
Sensor parameters from a personal computer.
DeviceNet
Configurator
PLC
Serial connector
Operating and monitoring Sensor settings from Configurator
• Setting and downloading Sensor data.
• Monitoring Sensor ON/OFF data, incident light levels, etc.
• Performing Sensor teaching operations.
DeviceNet
Fiber Sensors
DeviceNet slave
Type
Sensor parameter
Writes any parameters, including maximum
setting
sensitivity, and thresholds.
Sensor monitoring
Reads any parameters, including ON/OFF
data, incident light levels, and thresholds.
Sensor teaching
Performs various teaching operations.
Communications contents
Section 2-1
Conditions
Cannot be
used when
Mobile Con-
sole is con-
nected.

Advertisement