Explicit Message Communications
Write Timer Setting
Write Hysteresis Width
Write Custom Flags
38
Bit
Contents
05
Flashing Setting:
0: OFF
1: ON
06
Sensing Setting:
0: Standard
07
2: Super long-distance
3: Super high-speed
08
Timer Mode:
1: OFF-delay
09
2: ON-delay
3: One-shot
10
Number of Display Digits:
0: 4 digits
11
1: 3 digits
12
2: 2 digits
3: 1 digit
4: 0 digits
13
Always 0.
14
Teaching during RUN
0: OFF
1: ON
15
Eco Mode
0: OFF
1: ON
Writes the timer setting for the OFF-delay, ON-delay, or one-shot timer of the
Sensor for the unit number specified in the instance ID. The data is given as a
2-byte (4-digit) hexadecimal value. The value is set in ms. The setting range is
0000 Hex to 00C8 Hex, but the possible settings are restricted as follows:
Timer setting
0 to 20 ms
1-ms increments
20 to 200 ms
5-ms increments
An error will occur if a value is written that does not meet the above setting
interval conditions.
Writes the hysteresis width of the Sensor for the unit number specified in the
instance ID. The data is given as a 2-byte (4-digit) hexadecimal value.
Set whether the following settings for the Sensor of the unit number specified
in the instance ID can be set or monitored from the sensor key switch.
Bit
Contents
00
Hold Setting:
0: Enable
01
1: Not displayed
2: Disable
02
Flashing Setting:
03
0: Enable
1: Not displayed
2: Disable
Setting interval
Section 2-6