Omron E3X-DRT21 Operation Manual page 52

Fiber amplifier sensor communication units
Table of Contents

Advertisement

Explicit Message Communications
List of Operation
Commands
The following table lists the explicit messages operation commands.
Explicit
message
Adjust Maxi-
Specifies the unit number as the
mum Sensitivity
instance ID, and sets the maxi-
mum sensitivity when the com-
mand is sent.
Teach One
Specifies the unit number as the
Point
instance ID, and teaches one
point when the command is sent.
Teach First
Specifies the unit number as the
Point
instance ID, and teaches the first
point of two-point teaching when
the command is sent.
Teach Second
Specifies the unit number as the
Point
instance ID, and teaches the sec-
ond point of two-point teaching
when the command is sent.
Teach First
Specifies the unit number as the
Position
instance ID, and teaches the first
position when the command is
sent.
Teach Second
Specifies the unit number as the
Position
instance ID, and teaches the sec-
ond position when the command
is sent.
Start Zero
Specifies the unit number as the
Reset
instance ID, and starts the zero
reset operation when the com-
mand is sent.
Start Flashing
Specifies the unit number as the
instance ID, and starts flashing
when the command is sent.
Disable Zero
Specifies the unit number as the
Reset
instance ID, and disables the
zero reset operation when the
command is sent.
Stop Flashing
Specifies the unit number as the
instance ID, and stops flashing
when the command is sent.
Initialize Sensor
Specifies the unit number as the
Settings
instance ID, and resets all the
Sensor internal settings to the
default settings when the com-
mand is sent.
Reset
When the command is sent, all
the connected Sensors are reset
by turning the power OFF and
then ON again.
1. The unit number specified by the Instance ID must be set to between 0001
Hex and 0010 Hex.
2. An error will occur if the unit number of an E39-TM1 Terminal Block Unit is
specified.
Function
Service
code
16
16
16
16
16
16
06
16
07
07
05
05
Section 2-6
Command
Instance
Operation
ID
command
data
Unit
30
number
Unit
31
number
Unit
32
number
Unit
33
number
Unit
34
number
Unit
35
number
Unit
50
number
Unit
53
number
Unit
60
number
Unit
63
number
Unit
None
number
00
None
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

E3x-srt21E3x-cif11

Table of Contents