Omron E3X-DA-S Series Manual

Omron E3X-DA-S Series Manual

Advanced fiber amplifier units
Hide thumbs Also See for E3X-DA-S Series:

Advertisement

Quick Links

Digital Fiber Amplifier Unit
E3X-DA-S
Stable Detection with Advanced Fiber
Amplifier Units
• A wide range of added value with standard models with one
input and two outputs, and ultra-long-term APC models with an
APC life of approximately 20 years.
• Power turning to easily set the optimum light level.
• Automatic Power Control (APC) is always enabled to stabilize
emitter power with high accuracy.
• GIGA RAY for stable detection with the highest level of power in
this class even for low-reflective objects and large objects.
• The E3X-DA0-S supports an EtherCAT Sensor Communications
Unit or CompoNet Sensor Communications Unit.
Ordering Information
Fiber Amplifier Units
Pre-wired Models and Wire-saving Connector Models [Dimensions➜page 27]
Type
Appearance
Standard
models
Ultra-long-term
APC models
High-speed
response
models
*1. A Wire-saving connector sold separately is required.
*2. These models allow you to use an E3X-DRT21-S VER.3 Sensor Communications Unit. When using the E3X-DRT21-S VER.3, use an E3X-
CN02 Connector without a Cable for the Wire-saving Connector.
Sensor Communications Unit Connector Models (for EtherCAT and CompoNet) [Dimensions➜page 29]
Type
Appearance
Standard
Connector for Sensor Communications Unit
model
Connecting
method
NPN output
Pre-wired
E3X-DA21-S 2M
(2 m)
Wire-saving
E3X-DA7-S
*1
connector
Pre-wired
E3X-DA21R-S 2M
(2 m)
Wire-saving
E3X-DA7R-S
*1
connector
Pre-wired
E3X-DA21F-S 2M
(2 m)
Wire-saving
E3X-DA7F-S
*1
connector
Connecting method
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model
PNP output
E3X-DA51-S 2M
*2
*2
E3X-DA9-S
E3X-DA51R-S 2M
E3X-DA9R-S
E3X-DA51F-S 2M
E3X-DA9F-S
Model
E3X-DA0-S
Applicable wire-saving connector
(sold separately)
Type
Model
---
---
Master
E3X-CN21
connector
Slave
E3X-CN22
connector
---
---
Master
E3X-CN21
connector
Slave
E3X-CN22
connector
---
---
Master
E3X-CN11
connector
Slave
E3X-CN12
connector
Applicable Sensor
Communications Unit
E3X-ECT
E3X-CRT
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron E3X-DA-S Series

  • Page 1 • The E3X-DA0-S supports an EtherCAT Sensor Communications For the most recent information on models that have been certified for Unit or CompoNet Sensor Communications Unit. safety standards, refer to your OMRON website. Ordering Information Fiber Amplifier Units Pre-wired Models and Wire-saving Connector Models [Dimensions➜page 27]...
  • Page 2: Product Overview

    E3X-DA-S Accessories (sold separately) Wire-saving Connectors (Required for models for Wire-saving Connectors.) Protection stickers attached [Dimensions➜page 29] Type Appearance Cable length No. of conductors Model Master connector E3X-CN21 Slave connector E3X-CN22 Master connector E3X-CN11 Slave connector E3X-CN12 Note: The E3X-CN11/12 can also be used to connect to the E3X-DA@-S (@: 7/9) or the E3X-DA@R-S (@: 7/9), but the output lines will support only 1 channel.
  • Page 3 E3X-DA-S Ratings and Specifications Fiber Amplifier Units Type Standard models Ultra-long-term APC High-speed response Model for Sensor models models Standard models Communications Unit E3X-DA@-S E3X-DA@R-S E3X-DA@F-S Item Model E3X-DA0-S* (@: 21/51/7/9) (@: 21/51/7/9) (@: 21/51/7/9) Light source (wavelength) Red,4-element LED (625 nm) Supplied from the 12 to 24 VDC ±10%, connector through the...
  • Page 4 E3X-DA-S E3X-DA@-S E3X-DA@R-S E3X-DA@F-S Item Model E3X-DA0-S (@: 21/51/7/9) (@: 21/51/7/9) (@: 21/51/7/9) Digital display Select from incident level + threshold or other 6 patterns (Refer to 6. Display switch on page 21.) Display orientation Switching between normal / reversed display is possible. Key lock Key lock Key lock / Easy key lock.
  • Page 5 E3X-DA-S Sensing Distance E3X-DA@-S (@: 21/51/7/9/0) E3X-DA@F-S(@: 21/51/7/9) Threaded Models Sensing distance (mm) Sensing Sensing direction Size Model High-resolution Standard High-speed Super-high- method Tough mode mode mode mode speed mode E32-T11N 2M 2,000 1,400 1,000 Right-angle E32-LT11N 2M 4,000 4,000 3,500 2,300 Through-...
  • Page 6 E3X-DA-S E3X-DA@-S (@: 21/51/7/9/0) E3X-DA@F-S(@: 21/51/7/9) Sleeve Models Sensing distance (mm) Sensing Sensing direction Model High-resolution Standard High-speed Super-high- method Tough mode mode mode mode speed mode E32-T24R 2M Side-view E32-T24E 2M Through- E32-T21-S1 2M beam Top-view E32-T33 1M E32-TC200BR 2M 2,000 1,400 1,000...
  • Page 7 E3X-DA-S E3X-DA@-S (@: 21/51/7/9/0) E3X-DA@F-S(@: 21/51/7/9) High-power Beam Sensing distance (mm) Sensing Aperture Type Model High-resolution Standard High-speed Super-high- direction angle Tough mode mode mode mode speed mode Right-angle 15 ° E32-LT11N 2M 4,000 *2 4,000 *2 3,500 2,300 10 ° E32-T17L 10M 20,000 *1 20,000 *1...
  • Page 8 E3X-DA-S E3X-DA@-S (@: 21/51/7/9/0) E3X-DA@F-S(@: 21/51/7/9) Detection without Background Interference Sensing distance (mm) Sensing Sensing direction Model High-resolution Standard High-speed Super-high- method Tough mode mode mode mode speed mode E32-L16-N 2M 0 to 15 0 to 12 Flat-view Limited- E32-L24S 2M 0 to 4 reflective Side-view...
  • Page 9 E3X-DA-S E3X-DA@-S (@: 21/51/7/9/0) E3X-DA@F-S(@: 21/51/7/9) Bending-resistant Sensing distance (mm) Sensing Size Model High-resolution Standard High-speed Super-high- method Tough mode mode mode mode speed mode 1.5 dia. E32-T22B 2M E32-T21 2M Through- beam E32-T11 2M 2,500 1,800 1,350 Square E32-T25XB 2M 1.5 dia.
  • Page 10 E3X-DA-S E3X-DA@-S (@: 21/51/7/9/0) E3X-DA@F-S(@: 21/51/7/9) Vacuum-resistant Sensing distance (mm) Sensing Heat-resistant temperature Model High-resolution Standard High-speed Super-high- method Tough mode mode mode mode speed mode E32-T51V 1M 120 °C Through- E32-T51V 1M + E39-F1V 2,000 2,000 2,000 1,360 beam 200 °C E32-T84SV 1M 1,760...
  • Page 11 E3X-DA-S E3X-DA@R-S (@:21/51/7/9) Threaded Models Sensing distance (mm) Sensing Sensing direction Size Model High-resolution Standard High-speed Super-high- method Tough mode mode mode mode speed mode E32-T11N 2M 1,000 Right-angle E32-LT11N 2M 3,200 2,300 1,750 1,150 Through- E32-T11R 2M 1,000 beam Straight E32-LT11 2M 3,800...
  • Page 12 E3X-DA-S E3X-DA@R-S (@:21/51/7/9) Sleeve Models Sensing distance (mm) Sensing Sensing direction Model High-resolution Standard High-speed Super-high- method Tough mode mode mode mode speed mode E32-T24R 2M Side-view E32-T24E 2M Through- E32-T21-S1 2M beam Top-view E32-T33 1M E32-TC200BR 2M 1,000 E32-D24R 2M Side-view E32-D24-S2 2M E32-D43M 1M...
  • Page 13 E3X-DA-S E3X-DA@R-S (@:21/51/7/9) High-power Beam Sensing distance (mm) Sensing Aperture Type Model High-resolution Standard High-speed Super-high- direction angle Tough mode mode mode mode speed mode Right-angle 15 ° E32-LT11N 2M 3,200 2,300 1,750 1,150 10 ° E32-T17L 10M 20,000 *1 20,000 *1 20,000 *1 10,000...
  • Page 14 E3X-DA-S E3X-DA@R-S (@:21/51/7/9) Transparent Object Detection (Retro-reflective) Sensing distance (mm) Sensing Feature Size Model High-resolution Standard High-speed Super-high- method Tough mode mode mode mode speed mode E32-C31 2M + E39-F3R Film detection + E39-RP37 − Square E32-R16 2M 150 to 1,500 Retro- reflective Threaded Models...
  • Page 15 E3X-DA-S E3X-DA@R-S (@:21/51/7/9) Heat-resistant Sensing distance (mm) Sensing Heat-resistant temperature Model High-resolution Standard High-speed Super-high- method Tough mode mode mode mode speed mode 100 °C E32-T51R 2M 150 °C E32-T51 2M 1,400 1,000 Through- beam 200 °C E32-T81R-S 2M 350 °C E32-T61-S 2M 100 °C E32-D51R 2M...
  • Page 16 E3X-DA-S E3X-DA@R-S (@:21/51/7/9) FPD, Semiconductors, and Solar Cells Sensing distance (mm) Sensing Operating Application Model High-resolution Standard High-speed Super-high- method temperature Tough mode mode mode mode speed mode Glass presence detection E32-L16-N 2M 0 to 15 0 to 12 70 °C E32-A08 2M 10 to 20 Glass substrate alignment...
  • Page 17: I/O Circuit Diagrams

    E3X-DA-S I/O Circuit Diagrams NPN Output Operation Operation Model Timing charts Output circuit mode selector ch1/ Incident light E3X-DA21-S No incident light Operation indicator Operation indicator Display (orange) ch2 Brown LIGHT ON (orange) Opera- Light-ON (L-ON) Load Output transistor tion Black indicator Photo-...
  • Page 18: Operating Procedure

    E3X-DA-S Nomenclature Fiber Amplifier Units E3X-DA@-S (@: 21/51/7/9/0) Main Display (Red) Sub-Display (Green) Incident level, function, etc. Threshold, function settings, etc. Operation Keys Function setting Lock lever operations DOWN Locks the fiber unit. MODE Channel Selector Note: Nomenclature and operating procedures for the E3X- Operation Indicator Operation Indicator Use to select the channel to display and set.
  • Page 19 E3X-DA-S Teaching the Threshold (SET Mode) ✽ There are five methods that can be used for teaching, as described 4-3. Teaching a Reflective Fiber Unit without a Workpiece below. Use the method most suitable for the application. ✽ Two-point teaching, positioning teaching, and automatic teaching You can set the threshold to above the incident light level without can be performed in RUN Mode.
  • Page 20 E3X-DA-S Setting Functions (SET Mode) ✽ The function transition boxes show the default settings. ✽ ➜Refer to 4. Teaching the More functions may be displayed depending on the detailed settings. Moving between Functions Threshold on page 19. Teaching 0. Operation mode 1.
  • Page 21 E3X-DA-S Function Setting (display) Description Used to display the incident light level and the threshold. Incident level Threshold Used to display the incident light level as a percentage of the threshold and the threshold. % incident level Threshold Used to display the peak and bottom levels of incident Fixed interval light within a set time.
  • Page 22: Saving User Settings

    E3X-DA-S Convenient Functions 6-1. Setting the Digital Display to Zero (Zero Reset) 6-3. Resetting Settings (Initial Reset or User Reset) The incident light level on the main display can be set to 0. All settings can be returned to the factory defaults or to The incident light level and the threshold will both be user-saved settings.
  • Page 23 E3X-DA-S Nomenclature Fiber Amplifier Units E3X-DA@R-S (@: 21/51/7/9) Main Display (Red) Sub-Display (Green) Incident level, function, etc. Threshold, function settings, etc. Operation Keys Lock lever Function setting DOWN Locks the fiber unit. operations MODE Easy key lock Selector Operation Indicator APC alarm output Select to lock or unlock settings.
  • Page 24: Error Display

    E3X-DA-S Nomenclature Fiber Amplifier Units E3X-DA@F-S (@: 21/51/7/9) Main Display (Red) Sub-Display (Green) Incident level, function, etc. Threshold, function settings, etc. Operation Keys Lock lever Function setting DOWN Locks the fiber unit operations MODE Easy key lock Selector Operation Indicator Power tuning Select to lock or unlock settings.
  • Page 25: Safety Precautions

    E3X-DA-S Safety Precautions To ensure safe operation, be sure to read and follow the Instruction Manual provided with the sensor. Mounting WARNING Connecting and Disconnecting Wire-saving Connectors This product is not designed or rated for ensuring Mounting Connectors safety of persons either directly or indirectly. 1.
  • Page 26: Optical Communications

    E3X-DA-S Mounting the End Plate (PFP-M) Use an End Plate if the Amplifier Unit might move due to vibration. Protective cover Unlocked Locked End Plate Note: 1. To maintain the fiber unit properties, confirm that the lock Fiber Unit Connection is released before removing the fiber units.
  • Page 27: Pre-Wired Models

    E3X-DA-S (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Fiber Amplifier Units Pre-wired Models Digital Display Area ✽1. The indicators are as follows: E3X-DA21-S Indicator ✽1 E3X-DA21-S Operation indicator 15.6 35.25 E3X-DA51-S E3X-DA51-S (2 ch) E3X-DA21R-S...
  • Page 28: Din Track Mounting

    E3X-DA-S Wire-saving Connector Models Digital Display Area ✽1. The indicators are as follows: E3X-DA7-S Indicator ✽1 E3X-DA7-S Operation indicator E3X-DA9-S 15.6 35.25 E3X-DA9-S (2 ch) E3X-DA7R-S E3X-DA7R-S APC alarm output E3X-DA9R-S E3X-DA9R-S indicator E3X-DA7F-S E3X-DA7F-S Power tuning Operation indicator (1ch) Main display Sub-display E3X-DA9F-S...
  • Page 29: Master Connector

    E3X-DA-S Sensor Communications Unit Connector Models (for EtherCAT and CompoNet) E3X-DA0-S 32.8 11.7 29.8 15.1 11.75 12.15 3.25 Two, 2.4 dia. 5.65 28.1 18.7 34.8 44.3 Two, 3.2 dia. 28.1 Wire-saving Connectors Master Connector E3X-CN21 2,000 Edge of amplifier ✽ ✽...
  • Page 30: Mounting Brackets

    E3X-DA-S Master Connector E3X-CN11 2,000 Edge of amplifier ✽ ✽ Cable 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm , Insulator diameter: 1.1 mm) Slave Connector E3X-CN12 2,000 Edge of amplifier ✽ ✽ Cable 2.6-dia. vinyl-insulated round cable with 1 conductors (Conductor cross section: 0.2 mm , Insulator diameter: 1.1 mm) Accessories (sold separately) Mounting Brackets...
  • Page 31: Warranty

    Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON...
  • Page 32 IL 60173-5302 U.S.A. Carl-Benz-Str. 4, D-71154 Nufringen, Germany Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 Tel: (49) 7032-811-0/Fax: (49) 7032-811-199 © OMRON Corporation 2010 All Rights Reserved. OMRON (CHINA) CO., LTD. OMRON ASIA PACIFIC PTE. LTD. In the interest of product improvement, Room 2211, Bank of China Tower, No.

Table of Contents