Ricoh D197 Service Manual page 625

Hide thumbs Also See for D197:
Table of Contents

Advertisement

SP Mode Tables - SP3000
3320
[Vsg Adj: Execute]
P Sensor
3-320-001
Execute the Vsg adjustment for the ID sensor.
Vsg Error Counter
3-320-011
Displays Vsg error counter.
[Adjusted Vsg]
Displays regular reflection output of the bare ITB area at the Vsg
3321
adjustment.
Normal condition: 3.5 to 4.5V
3-321-001 Vsg reg
[Adjusted Ifsg]
Displays the LED current of the ID sensor. If it differs greatly from the
3322
value in SP3-322-011, the ID sensor may be stained, the OPC drum may
have deteriorated, the ID sensor may be out of alignment, or there may be
some other problem.
3-322-001 Ifsg
[Adjusted Ifsg]
3322
Displays the minimum LED current of the ID sensor for the Vsg
adjustment.
3-322-011 Ifsg Min
D197/D198/D199/D200/D201/D202
ENG
[Execute]
*ENG
[0 to 99 / 0 / 1times/step]
*ENG
[0.00 to 5.50 / 0.00 / 0.01V/step]
*ENG
[0.0 to 50.0 / 10.0 / 0.001mA/step]
*ENG
[0.0 to 50.0 / 27.0 / 0.001mA/step]
5-50