SP Mode Tables - SP5000-3
5-886-101 Skip LR Chech
[SD GetCounter]
This SP determines whether the ROM can be updated.
This SP sends a text file to an SD card inserted in SD card Slot 2 (lower
slot). The operation stores. The file is stored in a folder created in the root
5887
directory of the SD card called SD_COUNTER. The file is saved as a text
file (*.txt) prefixed with the number of the machine.
1. Insert the SD card in SD card Slot 2 (lower slot).
2. Select SP5887 then touch [EXECUTE].
3. Touch [Execute] in the message when you are prompted.
5-887-001 -
[Personal Information Protect]
5888
Selects the protection level for logs.
5-888-001 -
D197/D198/D199/D200/D201/D202
[0 or 1 / 0 / 1/step]
0: Version check for indivisual firmware
1: No version check for indivisual
firmware
When selecting "0", indivisual firmware
-
in the machine is not updated at the
package firmware updating.
Do not change this setting to "1"
normally. The setting "1" is only used
for a special order.
[- / - / -]
*CTL
[Execute]
[0 or 1 / 0 / 1/step]
0: No authentication, No protection for
*CTL
logs
1: No authentication, Protected logs
(only an administrator can see the logs)
5-192