Result Code
8 (DISK FULL)
9 (DEVICE ERROR)
10 (LOG ERROR)
20 (PART FAILED)
21 (INVALID FILE)
22 (INVALID KEY)
SM
Cause
The available storage
Execute the operation again after
space on the external
making sure there is enough storage
medium is insufficient.
space.
Failed to write or read
Check whether the path to the folder for
the log file.
storing the file or the folder in which the
file is stored is missing.
The hard disk is
Contact your supervisor.
faulty.
Failed to import some
The reason for the failure is logged in
settings.
"NgCode". Check the code.
Reason for the Error (Ng-Name)
2. INVALID VALUE
The specified value exceeds the
allowable range.
3. PERMISSION ERROR
The permission to edit the setting is
missing.
4. NOT EXIST
The setting does not exist in the system.
5. INTERLOCK ERROR
The setting cannot be changed because
of the system status or interlocking with
other specified settings.
6. OTHER ERROR
The setting cannot be changed for some
other reason.
Failed to import the
Check whether the file format is correct.
file because it is in the
The import file should be a CSV file.
wrong format in the
external medium.
The encryption key is
Use the correct encryption key.
not valid.
5-441