Communication Between Master Station And Remote I/O Stations; System Configuration; Setting Of Master Station - Mitsubishi FX2N-16CCL-M User Manual

Cc-link master module
Hide thumbs Also See for FX2N-16CCL-M:
Table of Contents

Advertisement

FX2N-16CCL-M CC-Link System Master Block
10.

Communication between Master Station and Remote I/O Stations

This chapter describes module setting, programming and operation check using a system
configuration example.
10.1

System Configuration

It is supposed that three remote I/O stations are connected in the system.
FX
1N
Series PLC
10.1.1

Setting of master station

The figure below shows the setting of the switches in the master station.
/FX
/FX
/FX
2N
3U
2NC
Remote I/O station
(station No. 1)
Input module
AJ65BTB1-16D
RUN
FX
-16CCL-M
2N
ERR.
MST
TEST1
TEST2
STATION
L RUN
NO.
L ERR.
´
10
POWER
´
1
4
MODE
B RATE
0
156K
1
625K
2
2.5M
3
5M
ON
4
10M
SW
OFF
ON
1
-
-
2
-
-
SW
E
3
-
-
M/S
R
4
CLR
HLD
R
PRM
5
-
-
O
TIME
6
-
-
7
-
-
R
LINE
8
-
-
SD
RD
Communication between Master Station and Remote I/O Stations 10
CC-Link master block
FX
-16CCL-M
2N
Terminal
resistor
Remote I/O station
(station No. 2)
Output module
AJ65BTB1-16T
Station number setting switch
0(×10)
0(×1)
Mode setting switch
0 (online)
Transmission speed setting switch
2 (2.5 Mbps)
Condition setting switch
Remote I/O station
(station No. 3)
Terminal
resistor
I/O module
AJ65BTB1-16DT
Make sure to set the
master station to 00.
SW
Setting
Description
1
OFF
2
OFF
3
OFF
4
OFF
5
OFF
6
OFF
7
OFF
8
OFF
Clear
10-1

Advertisement

Table of Contents
loading

Table of Contents