FX2N-16CCL-M CC-Link System Master Block
[Word information from the remote device station to the master station]
9) The data of the remote register (RWr) in the remote device station is automatically (for each
link scan) stored in the remote register (RWr) in the master station.
10)The PLC receives the data of the remote device station stored in the buffer memory
"remote register (RWr)" using the FROM instruction.
Master station
Remote register (RWr)
RWr0
RWr1
RWr2
RWr3
RWr4
RWr5
RWr6
RWr7
RWr8
RWr9
RWrA
RWrB
RWrC
RWrD
RWrE
RWrF
RWr10
RWr11
RWr12
RWr13
RWr14
RWr15
RWr16
RWr17
RWr18
RWr19
RWr1A
RWr1B
RWr1C
RWr1D
RWr1E
RWr1F
RWr20
RWr3B
Remote I/O station
(station No.1
: Occupies 1 station)
Remote device station
(station No. 2
: Occupies 2 stations)
Remote register (RWr)
RWr0
RWr1
RWr2
RWr3
RWr4
RWr5
RWr6
RWr7
Functions 5