5.5 Control
5.5

ESC+WK Job Name

Job Name
ESC
Hexadecimal
code
<1B>
16
Initial value
aaaaaaaaaaaaaaaa =<20>
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Specifying job name for status return.
[Format]
<WK>aaaaaaaaaaaaaaaa
●Parameter
a[Job Name]
=
ASCII code 16-digit, Shift JIS Kanji 8-digit
[Coding Example]
Job name: SATO
<A>
<ID>01
<WK>SATO
<V>200<H>100<P>0<$>B,100,100,6
<$=>SATOPRINTER
<Q>2
<Z>
[Supplementary Explanation]
1. When Status4 is used for interface protocol, specified job name can be set to the telegraphic status.
2. Status can be confirmed sending status request (ENQ).
3. Include this command within items and use between start of data transmission <A> and end of data transmission
<Z>.
4. This command can be used in combination with Job ID Number <ID>.
[Notes]
1. In status return interface protocol, this command becomes valid when status request (ENQ) is received while printing
(QTY≠0, includes at the time of Offline and Error).
2. In status return communication protocol, if status request (ENQ) is received when printing is not in progress (QTY=0,
No received data when power is ON), space (20H) will be set to status and returned.
3. When Job ID Number <ID> is used more than twice within the items of <A> and <Z>, the last specified value
becomes valid.
4. For more information, refer to the "Interface Specifications".
WK
Parameter
<57>
<4B>
aaaaaaaaaaaaaaaa
16
16
16
The set parameter is not maintained.
The set parameter is valid until the next valid setting.
The set command becomes invalid.
14
ESC+WK