10.3 2D code
10.3

ESC+2D20 MAXI Code

MAXI Code
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Specifying MaxiCode.
[Format](Setting part)
<2D20>,a(,bbb,ccc,d ~ d)
●Parameter
a [Mode]
=
* Following parameter must be specified when specifying mode 2 or mode 3.
When specifying mode 4 or mode 6, the parameter should be omitted.
b [Service class]
=
c [Country code]
=
d [Postal code]
=
[Format](Data part)
<DN>mmmm,n~n
●Parameter
m[Number of Data]
=
n [Print data]
=
Mode
Service class
2
Fixed 3 digits
3
(Numeric only)
4
6
[Coding Example]Mode:Transportation (Numericl only), Service class: 003, Country code: 081
Postal code: 123456789
<A>
<V>100<H>200<2D20>,2,003,081,123456789
<DN>0010,0123456789
<Q>2
<Z>
[Supplementary Explanation]
1. Size of MaxiCode are not changed by number of data for printing.
2. If parameter that is not described above is used, or print data doesn't match, symbol is not printed.
3. When specifying mode 4 and mode 6, number of print data must be specified over 12. When number of print
data is specified less than 11, scanner cannot read printed MaxiCode.
4. The maximum number of print data varies depending on the print data combination when using the print data
other than alphanumeric code.
5.Created module was modified to improve the quality. The module may be different from the previous one, but
the read result is the same.
2D20
<32>
<44>
<32>
<30>
16
16
16
16
2
:
Transportation (Numeric)
3
:
Transportation (Alphanumeric)
4
:
Standard symbol
6
:
Reader programing
Valid Range
:
001 to 999 (Numeric)
Valid Range
:
001 to 999 (Numeric)
Valid Range
:
0 to 999999999 (Mode 2)
000000 to 999999 (Mode 3)
* Mode 2: Max 9 digits (Numeric only)
Mode 3: Fixed 6 digits (Capital alphabet)
Valid Range
:
1 to 138
Data
*
00H cannot be specified.
Country code
Fixed 3 digits
(Numericl only)
(Alphanumeric)
Omission
167
ESC+2D20
Parameter
,a(,bbb,ccc,d~d)
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Maximum print data
Postal code
Numeric only
Max. 9 digits
Fixed 6 digits
123
138
Alphanumericl
84
93