Esc+Ru Uid Return(Iso/Iec15693) - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

16.9 RFID
16.9

ESC+RU UID Return(ISO/IEC15693)

UID Return(ISO/IEC15693)
Command
ESC
HEX code
<1B>
16
Default Value
aa=00
When turning off the power switch
Valid range and
Valid range within item
term of
command
Valid range between items
[Function]
This command is used to return UID together with the result when data is written to the RFID tag by the <RK>
.
command
[Format]
Return specification :<RU>,aa
Request to return:[DC2]PK
●Parameters6
Symbol
Parameter name
a
Identifier
[[DC2]PK return data format (normal)]
[STX]a...a,b,c,d...d[ETX]
[Return data]
Symbol
Parameter name
Total number of data byte
* This is the total number of bytes after parameter b.
a
The delimiting comma between parameters a and b,
and the ETX are not included.
Write result status
*Text format
b
Error symbol
c
UID return data
d
RU
Parameter
<52>
<55>
,aa
16
16
The set command is not maintained.
The set parameter is in effect until a new specification is
made.
The set parameter is in effect until a new specification is
made.
Valid range
00: Not returned (default setting)
01: Validate return.
Obtain return data by sending [DC2]PK.
345
ESC+RU
Two character fixation
Valid range
Data size from the first write result
status until before [ETX]
Maximum 5 digits
0: Write failure
1: Write success
Note: Specified in text format.
N:No error
U:UID read error
A:All errors
Note: Specified in text format
Refer to "UID return data" as below
Note: Specified in text format

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents