Samsung MIM–B18BN User & Installation Manual page 46

Hide thumbs Also See for MIM–B18BN:
Table of Contents

Advertisement

Appendix (Continued)
Initial Connection Error (for Private IP)
Several DMS2.5s are Connected to the Same Network
Computer
Computer cannot
distinguish which DMS2.5
has 192.168.0.100 IP.
In factory setting, all IP of DMS2.5 is same. Therefore, if you connect several
DMS2.5 to the same network, the computer cannot distinguish which DMS2.5 has
192.168.0.100 IP address.
Solution
- Connect only 1 DMS2.5 to the same network.
- Connect the power to only one DMS2.5 you want to use and cut the power for the
rest of DMS2.5.
- Disconnect from the network and set the IP again per each DMS2.5.
Then connect to the network again.
46
E-
DMS2.5 ①
Initial IP : 192.168.0.100
DMS2.5 ②
Initial IP : 192.168.0.100
DMS2.5 ③
Initial IP : 192.168.0.100
DMS2.5 ④
Initial IP : 192.168.0.100

Hide quick links: