Samsung MIM–B18BN User & Installation Manual

Hide thumbs Also See for MIM–B18BN:

Advertisement

Air Conditioner

user & installation manual
EN
DB68-06095A-01
DMS2.5(Data Management Server2.5)
MIM-D01AN
MIM-D01AUN
BACnet Gateway
MIM-B17BN
LonWorks Gateway
MIM-B18BN
imagine
the possibilities
Thank you for purchasing this Samsung product.
For more information on using the
product, download the user manual
from the product and refer to it.

Advertisement

Table of Contents
loading

Summary of Contents for Samsung MIM–B18BN

  • Page 1: Air Conditioner

    BACnet Gateway MIM-B17BN LonWorks Gateway MIM-B18BN Air Conditioner user & installation manual For more information on using the product, download the user manual from the product and refer to it. imagine the possibilities Thank you for purchasing this Samsung product. DB68-06095A-01...
  • Page 2: Safety Precautions

    Safety Precautions English Cautions for operation Before using the DMS2.5, BACnet Gateway, LonWorks Gateway, read carefully these instructions. After reading the instructions, keep this user's manual in a handy and safe place. If a user is changed, you must hand over the manuals. Never attempt to install the air conditioning system or to move the product by yourself.
  • Page 3 Consignes de sécurité Français Précautions pour le fonctionnement Avant d’utiliser le DMS2.5, BACnet Gateway, LonWorks Gateway, lisez attentivement ces consignes. Après en avoir pris connaissance, conservez ce manuel d’utilisation dans un lieu sûr et à portée de main. En cas de changement d’utilisateur, vous devez remettre les manuels. Ne tentez jamais d’installer le climatiseur ou de déplacer le produit par vous-même.
  • Page 4: Table Of Contents

    Contents AFETY RECAUTIONS ......RACKING ..........DMS2.5 EFORE NSTALLING THE ETTING THE OWER ISTRIBUTION ..... CCESSORIES ..........PPENDIX ..........IEWING THE ARTS ........ ATEWAY SETTING ....’ RODUCT IMENSIONS ......IEWING ORKS ATEWAY ARTS YSTEM RCHITECTURE ......RODUCT IMENSIONS ......OMPATIBLE EVICES ......
  • Page 5: Before Installing The Dms2.5

    A static IP from an internet service provider must be used if xDSL (ADSL, VDSL) is supported. Use this product only in a separate dedicated network. Samsung electronics is not liable for any problems caused by connecting it to the Internet or an intranet.
  • Page 6: Accessories

    Accessories Make sure you have each item. Supplied items may vary depending on your country or service provider. M4 x16 Item DMS2.5 Adapter Power cable Screw Quantity MIM-D01AN MIM-D01AUN Shape User & Installation Cable tie manual The DMS2.5 must be installed by a trained installer. Ensure the main power is turned off before installing the DMS2.5.
  • Page 7: Viewing The Parts

    Viewing the Parts Main Parts DMS2.5 Exterior LCD Display Shows current time and IP address. Various messages will be displayed depending on button input. LCD operation button There are 4 buttons(Menu, ▼(Down), ▲(Up), Set) and you can access menu and move, check the menu.
  • Page 8 Viewing the Parts (Continued) DMS2.5 Cable Connection Part RS485 Communication Terminal DI Terminal1 DI Terminal2 DO Terminal3 DO Terminal4 Reserved Serial Terminal Cable tie groove Power Terminal SD Card Socket Ethernet Terminal Reset Button Name Description DI Terminal1 Digital Input connection terminal, Channel1~Channel5 DI Terminal2 Digital Input connection terminal, Channel6~Channel10 DO Terminal3...
  • Page 9: Product Dimensions

    Main Parts DMS2.5 Interior Display Board 20-pin Cable Main Board 40-pin Cable Sub Board Note If you need external circuit configuration, consult with the manufacturer. Refer to page 18 for DI contact input operation. Product Dimensions 64.80 (Unit : mm)
  • Page 10: System Architecture

    System Architecture S-NET 3 Web Client TCP/IP Internet DMS2.5 Touch PM 05:45 OnOff Centralized Controller controller R5 485 RMS Center SIM/PIM Outdoor Unit Power Meter Max 256 Indoor units (DVM Series) Connecting outdoor unit and DMS2.5. - You can control up to 80 outdoor units and 256 indoor units by using DMS2.5. You can connect up to 16 (outdoor) units per each communication channel of the DMS2.5.
  • Page 11: Compatible Devices

    ( Please consult Samsung for compatible power meters) Watt-hour Meter Connected with PIM Pulse type Pulse Width: 20~400(ms) Pulse: 1~10000(Wh/Pulse) Products with ‘* ’ are not Samsung products and must be purchased separately. (Only selected power meters may be used for protocol compatibility issues.)
  • Page 12 Compatible Devices (Continued) Maximum Devices Attachable Devices Max. Note Tracking error occurs if exceeded The maximum number of indoor units Indoor Unit (including ERV and MCU) that can be connected to each DMS communication channel is 128. OnOff controller/ Must not exceed 15 units per each RS485 communication terminal Touch Centralized controller Must not exceed 16 units per each...
  • Page 13: Installing The Dms2.5

    Installing the DMS2.5 Separate the installation plate on the rear side of DMS2.5. Fix the installation plate on the wall using 4 screws. Hang the DMS2.5 on the groove which is on the top of the installation plate. Installation plate Fix the installation plate and DMS2.5 using 2 screws.
  • Page 14 Installing the DMS2.5 (Continued) Connecting Outdoor Unit Unfasten the 2 screws on the bottom of the DMS2.5 front cover. Hold the bottom 2 sides of the DMS2.5 and push downwards to slide open the cover. Connect the adapter to the power terminal. Arrange the adapter as the right figure.
  • Page 15 Connecting SIM Unfasten the 2 screws on the bottom of the DMS2.5 front cover. Hold the bottom 2 sides of the DMS2.5 and push downwards to slide open the cover. Connect the adapter to the power terminal. Arrange the adapter as the right figure. Adapter Separate 1 terminal block from 5 terminal blocks which are attached to RS485 communication terminal.
  • Page 16 Installing the DMS2.5 (Continued) Using the DI External Contact Control (Optional) Setting the External Contact Control Pattern You can set the system settings through contact control pattern. Select [System Settings] menu and click [System environment setting]. Click [Edit] from ‘Select the contact control pattern’ . Select the pattern you want to check.
  • Page 17 Contact control Pattern Pattern Control ▶ No external input (Factory default setting) Pattern1 When you input contact control signal in port 1, there will be no response. ▶ Level input (Emergency stop) 1. If the contact control signal is changed to ON, emergency stop status and all the indoor units are given ‘Stop’...
  • Page 18 Installing the DMS2.5 (Continued) DI(Digital Input) Circuitry according to Contact control Pattern Pattern 2 (May be used for connection with a fire sensor) DMS2.5 Emergency Stop/Resume Operation No Connection Pattern 3 (External contact signal control) DMS2.5 Operation/Stop A/C Enable/Disable remote control Pattern 4 (Pulse signal control) DMS2.5 Operation...
  • Page 19: Environment

    Setting the Computer Environment Device related to network (Purchase separately) Computer with a LAN Card HUB or network cable(Cross·Direct cable) Computer web browser specification Internet Explorer 11 or later version Silverlight 2.0 or later version Note A cross cable is used when connecting to PC directly. It is produced as transmission and reception cables are crossed.
  • Page 20 Setting the Computer Environment (Continued) Computer Settings for DMS2.5 Connection All settings of DMS2.5 will be arranged in web page which built in DMS2.5. You should access to DMS2.5 IP to use DMS2.5 web page. Set your computer settings as follows. DMS2.5 Factory default setting DMS2.5 IP : 192.168.0.100 IP Setting (Recommended)
  • Page 21: Setting The Dms2.5

    Setting the DMS2.5 DMS2.5 Connection and Login Address bar Click internet explorer icon( ) twice on your computer. When internet explorer window appears, enter IP address (https://192.168.0.100) on the address field then press [ENTER]. 1) At initial access, security certificate warning popup message will appear as shown.
  • Page 22 Setting the DMS2.5 (Continued) 2) Registering DMS2.5 certificate on web browser A. Select ‘Content’ tap in ‘Tools’ ‘Internet options’, and click ‘Certifi cates’. B. Select ‘Trusted Root Certifi cation Authorities’ and click ‘Import’. C. Click ‘Next’.
  • Page 23 D. Select ‘Browse’ and fi nd DMS2.5 certifi cate, and click ‘Next’. DMS2.5 certifi cate can be downloaded from [System environment setting]. E. Select ‘Place all certifi cates in following drive’ and click ‘Next’. F. Click ‘Finish’, and click ‘Yes’ when security warning appears.
  • Page 24 Setting the DMS2.5 (Continued) If it is the first time to access DMS2.5, “ Install Microsoft Silverlight” message will appear. If Microsoft Silverlight has already been installed, the screen will not appear. Click [Run] button and continue installation. After installation, access DMS2.5 again. Silverlight operates normally with Windows 7 or later version.
  • Page 25 Enter ID and password when DMS2.5 main web page appears. Then click [LOGIN]. Depending on authorization settings set by the administrator, access to some functions may be restricted. For user authorization setting, refer to System settings User authorization management. The default DMS2.5 user ID is ‘admin’ and password is ‘ac0530’ . Note Only authorized users can access to web page.
  • Page 26 Setting the DMS2.5 (Continued) DMS2.5 System Environment Setting (Network settings) You can set and check information about DMS2.5 installation operation. DMS2.5 Network Information Setting Select [System Settings] menu and click [System environment setting]. Click [Edit] from DMS2.5 network information window. When text boxes of IP address, subnet mask address, default gateway and DNS server are enabled, enter values for each item.
  • Page 27 (ex: an office LAN), it could be a risk of illegal approach. Also, this may change it to a harmful connection for other network devices. This is not the responsibility of Samsung Electronics and not included in compensation for the damage.
  • Page 28 Setting the DMS2.5 (Continued) System Time Setting Select [System Settings] menu and click [System environment setting]. Click [Edit] from system time setting. Enter system time(year/month/day/hour/minute/second). You can enter only numbers. Year: You can enter from 1980 to 2035. Month: You can enter from 1 to 12. Day: You can enter from 1 to 31.
  • Page 29 Setting the Language Select [System Settings] menu and click [System environment setting]. Click [Edit] from language selection. Select a language you want then click [Save]. Click [OK] when “This operation needs DMS2.5 to be restarted. Do you want to apply the setting?” message appears. Click [OK] and current web browser will be closed.
  • Page 30 Setting the DMS2.5 (Continued) DMS2.5 Name Setting Select [System Settings] menu and click [System environment setting]. Click [Edit] from DMS2.5 name setting window. Enter name of DMS2.5 when DMS2.5 name field enabled. You can use maximum 30 letters including English alphabets and special symbols.
  • Page 31 Error Mail Forwarding Setting Select [System Settings] menu and click [System environment setting]. Click [Edit] from error mail forwarding setting. Set all the items as the value you want when all items fields are enabled. If you select ‘Apply’ , you should enter e-mail address, SMTP server ID, password, and SMTP server address.
  • Page 32 Setting the DMS2.5 (Continued) Setting Enable public IP Select [System Settings] menu and click [System environment setting]. Click [Edit] on Enable public IP section. Select whether to use Public IP or not. When you select ‘Enable’ , you must register the Public IP of PCs or network devices to access DMS2.5 from the PCs or network devices.
  • Page 33: Main Menu

    System setting initialization 192.168.0.100 06:12:13(AM) Press [Menu], [ ], [ ] or [Set] on LCD if IP and current time are displayed on LCD screen. Main menu screen appears. Initialization is not possible in the screen which time information is displayed.
  • Page 34: Racking

    Tracking What is tracking? Tracking is an operation that finds devices which are connected to DMS2.5. Through tracking operation, devices which are connected to DMS2.5 can recognize if they are connecting to DMS2.5. To supervise and control system air conditioner using DMS2.5, tracking should be done first. Things you can do through tracking Checking the number of devices installed, setting communication mode for each channel, DVM tracking, Renaming is possible through tracking.
  • Page 35 Setting Communication Mode for Each Channel Select [System Settings] menu and click [Tracking]. Click [Edit] from communication mode for each channel setting. [Edit] will change to [Cancel]. Selection buttons are enabled. However, the channels which have searched device maintains its selection button disabled. When each channel is enabled, check the communication mode you want to set for each channel.
  • Page 36 Tracking (Continued) DVM Tracking Select [System Settings] menu and click [Tracking]. Click [DVM Tracking]. Enter administrator’s password and then click [OK]. Tracking information window pops up. Check it and click [OK] to continue. Execute tracking depending on the communication mode set by communication mode setting for each channel.
  • Page 37 Tracking completed message will appear. Select Zone initialization mode you want. No initialization: No zone information initialization will be made. Individual initialization: Initialize zone information as individual mode. - Individual mode: Arrange by indoor unit main address on monitoring page. Group initialization: Initialize zone information as group mode.
  • Page 38 Tracking (Continued) Disconnect All Devices Function Initialize searched device status in DMS2.5. Monitoring and controlling of all the connected devices to DMS2.5 will be stopped when you use this function. Connect searched device to the other channel and execute tracking. If the other device is searched in the channel you want to use, use ‘Disconnect all devices’...
  • Page 39 Renaming the Device Select [System Settings] menu and click [Tracking]. Click [Edit] on the bottom of tracking device list. [Edit] will change to [Cancel]. When the type of the device is displayed, NEW communication address will be shown with it. Note If you press [Cancel] button, [Cancel] will change to [Edit], and the changed name of device will be restored to original name.
  • Page 40 Tracking (Continued) DMS DI•DO Port Setting Select [System Settings] and then click [Tracking]. Click [Setting] which is next to DMS DI•DO of device list. Click [Edit] which is on the bottom of DMS DI•DO setting page. [Edit] will change to [Cancel]. Edit each item when DMS DI•DO selection and input fields are activated.
  • Page 41: Pim Setting

    PIM Setting Click [System Settings] [Tracking] when DMS2.5 web page menu screen appears. Click [Setting] which is next to PIM of device list. Enter administrator’s password and then click [OK]. Click [Edit] which is on the bottom of PIM setting page. [Edit] will change to [Cancel].
  • Page 42: Etting The Power Distribution

    Setting the Power Distribution When doing power distribution, set SIM/PIM channel for each indoor unit. Channel Setting by Indoor Unit Click [EHP Power Consumption Inspection] [Channel setting by indoor unit] when DMS2.5 web page menu screen appears. Click [Edit] when the setting channel by indoor unit screen appears.
  • Page 43 Check the virtual channel information of indoor/outdoor unit. To execute power distribution without SIM/PIM, you should set virtual channel. When bringing indoor unit’s power from outdoor unit, set the ‘Outdoor unit virtual channel’ information only. ( ‘Outdoor unit virtual channel’ is referring to watt-hour meter which is connected to outdoor unit.) When bringing indoor unit’s power from the other device, not from outdoor unit, set the ‘Outdoor unit virtual channel’...
  • Page 44: Ppendix

    Appendix IP Terminology DMS2.5 needs IP address to contact other computers. 1. Public IP Static IP 1-1. Dynamic IP 1-2. Static IP 2. Private IP 2-1. Dynamic IP 2-2. : Ordinary IP used to connect internet is called 1. Public IP public IP.
  • Page 45 Examples of DMS2.5 Installation with DSL Local Management without External Control : Use Private IP Direct connection between DMS2.5 and computer or controller Computer DMS2.5 Cross cable Private IP : 192.168.0.100 Private IP : 192.168.0.1 (Mount separate LAN card) Direct connection between DMS2.5 and computer or controller through HUB Computer DMS2.5 Private IP :...
  • Page 46 Appendix (Continued) Initial Connection Error (for Private IP) Several DMS2.5s are Connected to the Same Network Computer DMS2.5 ① Initial IP : 192.168.0.100 Computer cannot distinguish which DMS2.5 DMS2.5 ② has 192.168.0.100 IP. Initial IP : 192.168.0.100 DMS2.5 ③ Initial IP : 192.168.0.100 DMS2.5 ④...
  • Page 47: Bacnet Gateway Setting

    BACnet Gateway setting System Architecture BMS system BMS Engineering Internet SAMSUNG Engineering BACnet Gateway Touch PM 05:45 OnOff Touch Centralized Controller Control & Schedule Settings Centralized Monitoring controller controller RS 485 Outdoor Unit Max 256 Indoor units (DVM Series) Connecting outdoor units and BACnet Gateway - You can control up to 80 outdoor units and 256 indoor units using BACnet Gateway.
  • Page 48 Pulse Width: 20~400(ms) Pulse: 1~10000(Wh/Pulse) Products with ‘* ’ are not Samsung products and must be purchased separately. (Only selected power meters may be used for protocol compatibility issues.) Samsung is not responsible for BMS engineering which creates each device and objects.
  • Page 49 Maximum Devices Attachable Devices Max. Note Tracking error occurs if exceeded The maximum number of indoor units (including Indoor Unit ERV and MCU) that can be connected to each communication channel is 128. OnOff controller/ Must not exceed 15 units per each RS485 Touch communication terminal Centralized...
  • Page 50 BACnet Gateway setting (Continued) Setting the BACnet Gateway BACnet Gateway Connection and Login Click internet explorer icon( ) twice on your computer. When internet explorer window appears, enter IP address (https://192.168.0.100) on the address bar then press [ENTER]. If it is the first time to access BACnet Gateway, “ Install Microsoft Silverlight”...
  • Page 51 If you use accounts with authorization level lower than management group or accounts with general authorization level, you cannot access BACnet Gateway settings. If you cannot access BACnet Gateway, consult the manager. If you login successfully, 'Control and Monitoring' screen will appear.
  • Page 52 BACnet Gateway setting (Continued) Reading EHP Watt-hour Meter Setting and checking watt-hour meter Click [System and Checking Watt-hour meter]. You can change settings on watt-hour meter only when SIM/PIM interface module is connected. Click [Edit] from the 'Setting and checking Watt-hour meter' screen. CT proportion is set to ‘1’...
  • Page 53 Monthly baseline setting Click [System and Checking Watt-hour meter]. Click [Edit] from the ‘Monthly baseline setting’ screen. You can make changes when list box enables. Set the Monthly baseline setting. You can select from 1 ~ 31. If you select the last day of the month, it will automatically set the last day of corresponding month as baseline.
  • Page 54: System Settings

    BACnet Gateway setting (Continued) System Settings You can set and check information about BACnet Gateway installation and operation. BACnet Gateway network information Click [System Settings]. Click [Edit] from the ‘BACnet network information’ section. When text boxes of IP, Subnet mask, Default gateway, DNS server, BBMD IP, BBMD PORT, Network No., and BACnet PORT are enabled, enter the address values for each item.
  • Page 55 BACnet gateway information and initialization Click [System Settings]. You can check the basic BACnet gateway information from 'BACnet gateway information' section. Click [Edit] from the ‘BACnet gateway information’ section. If you want to initialize ‘Recipient_list’ , Check and click [Save]. When the pop-up window appears, click [OK].
  • Page 56 BACnet Gateway setting (Continued) Device Configuration Checking device information Click one of the Object ID from 'Object ID' column. Detail information of the selected device will be displayed in device information. Analog data of the selected device will be displayed in Analog data. Object ID: Displays ID of the corresponding object.
  • Page 57 BACnet Protocol Implementation Conformance Statement Date: 2016. 01. 11 Vendor Name: SAMSUNG Electronics CO., Ltd. Product Name: DMS BACnet Gateway Product Model Number: MIM-B17BN Application Software Version: 1.20 Firmware Revision: 1.20 BACnet Protocol Revision: 2.0 Product Description: This product supports BACnet/IP and provide functions to monitor and control status of air conditionerss.
  • Page 58 BACnet Gateway setting (Continued) SUPPORTED BIBB NAME SUPPORTED REMARKS BIBBS AE-N-A Alarm&Event-Notification-A Optional AE-N-I-B Alarm&Event-Notification Internal-B Support AE-N-E-B Alarm&Event-Notification External-B AE-ACK-A Alarm&Event-ACK-A AE-ACK-B Alarm&Event-ACK-B Alarm and AE-ASUM-A Alarm&Event-Summary-A Event AE-ASUM-A Alarm&Event-Summary-B Management AE-ESUM-A Alarm&Event-Enrollment Summary-A AE-ESUM-B Alarm&Event-Enrollment Summary-B AE-INFO-A Alarm&Event-Information-A AE-INFO-B Alarm&Event-Information-B AE-LS-A...
  • Page 59 SUPPORTED BIBB NAME SUPPORTED REMARKS BIBBS DM-R-A Restart-A DM-R-B Restart-B DM-LM-A List Manipulation-A DM-LM-B List Manipulation-B DM-OCD-A Object Creation & Deletion-A Device and DM-OCD-B Object Creation & Deletion-B Network DM-VT-A Virtual Terminal-A Management DM-VT-B Virtual Terminal-B NM-CE-A Connection Establishment-A NM-CE-B Connection Establishment-B NM-RC-A Router Configuration-A...
  • Page 60 If this product is a communication gateway, describe the types of non-BACnet equipment/ networks(s) that the gateway supports: This gateway switches SAMSUNG air conditioner protocol to BACnet protocol to make RS-485 communication possible with the air conditioners connected to gateway.
  • Page 61 Detail Description of Object Device Following table shows regulation of device ID and they are created automatically. DNET – Range CPP – Range INDOOR – Range Item [Digit 2] [Digit 3] [Digit 2] Centralized Controller 1~40 000~015 (OnOff Controller) SIM/PIM 1~40 100~115 DMS DI/DO...
  • Page 62: Indoor Unit

    BACnet Gateway setting (Continued) BACnet Point List Indoor Unit Single indoor unit has following point list. Unit Status value Instance Object Object Object Name Inactive Active Number Type Text-1 Text-2 Text-3 Text-4 Text-5 °C Indoor Temperature AC_RoomTemp_xx_xxxxxx °C Set temperature AC_Temp_Set_xx_xxxxxx °C Setting lower temperature limit...
  • Page 63 AHU Kit Single AHU unit has following point list. Unit Status value Instance Object Object Object Name Inactive Active Number Type Text-1 Text-2 Text-3 Text-4 Text-5 Indoor Temperature AHU_RoomTemp_xx_xxxxxx °C Set temperature AV AHU_Temp_Set_xx_xxxxxx °C Setting lower temperature AV AHU_Cool_LimitTemp_xx_xxxxxx °C limit Setting upper temperature...
  • Page 64 BACnet Gateway setting (Continued) Single EHS Unit has following point list. Unit Status value Instance Object Object Object Name Inactive Active Number Type Text-1 Text-2 Text-3 Text-4 Room temperature EHS_RoomTemp_xx_xxxxxx °C Use when displayed temperature type Set temperature EHS_Temp_Set_xx_xxxxxx °C is set to 'Room' .
  • Page 65 ERV, ERV Plus Single ERV or ERV Plus unit has following point list. Unit Status value Instance Object Object Object Name Inactive Active Number Type Text-1 Text-2 Text-3 Text-4 Text-5 Power On/Off operation ERV_Power_xx_xxxxxx Filter sign status ERV_FilterSign_xx_xxxxxx False True Filter sign reset ERV_FilterSign_Reset_xx_xxxxxx False...
  • Page 66 BACnet Gateway setting (Continued) SIM/PIM Single SIM/PIM has following point list. Instance Object Object Object Name Status value Number Type SIM/PIM error code SIM_Error_Code_xx_xx Refer to list of error code When the error occurred, send event to list SIM/PIM Notify SIM_Notify_xx_xx of destination in the recipient_list.
  • Page 67 BACnet Gateway BACnet Gateway has following point list. Instance Control and Object Object Name Status Value Number Monitoring Type All device OFF ALL_OFF_xx Inactive : All devices Off 0: Normal, 8: Emergency stop, 105 : Tracking in progress, DMS2.5 Status DMS2.5_Status_xx 108 : Tracking failed 109 : DMS2.5 ↔...
  • Page 68: Other Information

    BACnet Gateway setting (Continued) Other Information Object setting when there is communication error If any communication error occurs between the air conditioner devices, the property will be set as below. 1. Reliability property will be set as COMMUNICATION_FAILURE. 2. Fault / Alarm flag of Status_Flags property will be set as TRUE. 3.
  • Page 69: Parts

    Viewing LonWorks Gateway’s Parts Main Parts LonWorks Gateway Exterior LCD Display Shows current time and IP address. Various messages will be displayed depending on button input. LCD operation button There are 4 buttons(Menu, (Down), (Up), Set) and you can access menu and move, check the menu.
  • Page 70 Viewing LonWorks Gateway’s Parts (Continued) LonWorks Gateway Cable Connection Part RS485 Communication Terminal DI Terminal1 DO Terminal3 DO Terminal4 DI Terminal2 Lon Terminal Reserved Serial Terminal Cable tie groove Power Terminal SD Card Socket Reset Button Ethernet Terminal Name Description DI Terminal1 Digital Input connection terminal, Channel1~Channel5 DI Terminal2...
  • Page 71: Roduct Dimensions

    LonWorks Gateway Interior Display Board 20-pin Cable LonWorks Board 2-pin Cable 10-pin Cable Main Board 40-pin Cable Sub Board Note If you need external circuit configuration, consult with the manufacturer. Product Dimensions (Unit : mm) 64.80...
  • Page 72: On Works Gateway Setting

    LonWorks Gateway setting LonWorks Gateway setting System Architecture BMS system BMS Engineering Internet SAMSUNG Engineering LonWorks Gateway OnOff Touch PM 05:45 controller Centralized controller RS 485 Outdoor Unit Max 128 Indoor units (DVM Series) Connecting outdoor units and LonWorks Gateway - You can control up to 80 outdoor units and 128 indoor units using LonWorks Gateway.
  • Page 73 Pulse Width: 20~400(ms) Pulse: 1~10000(Wh/Pulse) Products with ‘* ’ are not Samsung products and must be purchased separately. (Only selected power meters may be used for protocol compatibility issues.) Samsung is not responsible for BMS engineering which creates each device and objects.
  • Page 74 LonWorks Gateway setting (Continued) Maximum Devices Attachable Devices Max. Note Tracking error occurs if exceeded The maximum number of indoor units Indoor Unit (including ERV and MCU) that can be connected to each communication channel is 128. OnOff controller / Must not exceed 15 units per each RS485 communication terminal Touch Centralized controller...
  • Page 75 Installing the LonWorks Gateway Commision ● Commision using Service Pin To activate the Service Pin, press and hold [SET] button for more than three seconds while time is displayed in the LCD Display window of the front side of LonWorks Gateway. Press and hold the [SET] button for more than 3 seconds.
  • Page 76 LonWorks Gateway setting (Continued) Control and Monitoring Item ● Functional classification by a device. The functions provided can be different according to the type of the connected device. Fresh Remarks Indoor ERV NV Name Duct 1 nviOnOff ON/OFF command 2 nviApplicMode Setting operating mode 3 nviSetpoint Setting desirable temperature...
  • Page 77 Although the LonWorks Gateway can connect 128 units, the actual number of available items can differ according to the number of indoor units connected. When the number of indoor units is increased, the number of controllable items will be decreased; on the other hand, as the number of indoor units decreases, the controllable items increase.
  • Page 78 LonWorks Gateway setting (Continued) Setting the LonWorks Gateway LonWorks Gateway Connection and Login Click internet explorer icon( ) twice on your computer. When internet explorer window appears, enter IP address (http://192.168.0.100) on the address bar then press [ENTER]. If it is the first time to access LonWorks Gateway, “ Install Microsoft Silverlight” message will appear.
  • Page 79 If you login successfully, 'Control and Monitoring' screen of DMS2.5 will appear. Click [System Setting]➔[LonWorks configuration] menu to switch to LonWorks Gateway. If you use accounts with authorization level lower than management group or accounts with general authorization level, LonWorks configuration will not be displayed on the menu.
  • Page 80 LonWorks Gateway setting (Continued) Monthly baseline setting Click [Setting and Checking Watt-hour meter]. Click [Edit] from the ‘Monthly baseline setting’ screen. You can make changes when list box enables. Set the Monthly baseline setting. You can select from 1~31. If you select the last day of the month, it will automatically set the last day of corresponding month as baseline.
  • Page 81 Device Configuration Checking and changing the Object ID List of equipment connected to LonWorks can be checked when the tracking is completed. Device Type, Address, Name and Object ID will appear. Object IDs are assigned in order from 1 to 128 when initial tracking is executed.
  • Page 82 LonWorks Gateway setting (Continued) Overview for Function Followings are the NV lists of indoor unit(ERV/AHU kit/Fresh ducts) supported by LonWorks Gateway. 1) nvi type - Data setting is allowed 2) nvo type - Data setting is not allowed Please refer to Message Definition for Setting value. 1.
  • Page 83 2. DMS system Objects NV Name NV Type Remarks nviDigitalOut[6] SNVT_ switch Control Digital output of DMS nviAllOff SNVT_hvac_emerg Control all indoor unit / ERV OFF nvoDigitalOut[6] SNVT_ switch Display Digital output status of DMS nvoDigitalIn[8] SNVT_ switch Display Digital input status of DMS nvoSystemLock SNVT_switch Display System Lock status of DMS...
  • Page 84 LonWorks Gateway setting (Continued) Network Parameter Chart Indoor/ERV/AHU kit/Fresh ducts objects SSACIndoor[nn](object id = 1-128) nvoSpaceTemp SNVT_temp_p nvoApplicMode nviOnOff SNVT_hvac_mode SNVT_switch nvoSetPoint nviApplicMode SNVT_temp_p SNVT_hvac_mode nvoOnOff nviSetPoint SNVT_switch SNVT_temp_p nvoFanStatus SNVT_switch nviFanStatus SNVT_switch nvoERVMode SNVT_count nviERVMode nvoErrorCode SNVT_count SNVT_count nviFilterReset nvoDeviceAlarm SNVT_switch SNVT_state...
  • Page 85 DMS system objects SSACSystem(object id = 129) nvoDigitalOut[6] SNVT_switch nviDigitalOut[6] SNVT_switch nvoDigitalIn[8] SNVT_switch nviAllOff SNVT_hvac_emerg nvoSystemLock SNVT_switch nvoDMSAlarm SNVT_count nvoSystemAlarm SNVT_count Configuration Properties nciSndHrtBt nciMinOutTm nciMinDeltaTemp nciDelayStatrup...
  • Page 86 LonWorks Gateway setting (Continued) Message Definition Data for Indoor Device ● nvoSpaceTemp(11) Description Indoor temperature SNVT_temp_p: Signed Long, 2 bytes SNVT Type Range: -10.00 °C ~ 50.00 °C Value and operation ● nvoApplicMode(12), nviApplicMode(2) Description Operation Mode status SNVT_hvac_mode: Enumeration(hvac_t) SNVT Type 0: HVAC_AUTO 1: HVAC_HEAT...
  • Page 87 ● nvoFanStatus(15), nviFanStatus(4) Description Fan Speed and direction SNVT_switch: Unsigned/signed Short SNVT Type Value State Auto High Value and operation Turbo Any>5.0 Auto Stop Up-Down ❈ Supporting modes are different according to indoor units. - Indoor unit: Auto, Low, Mid, High (Turbo : Optional) - ERV : Mid, High, Turbo - AHU Kit: High * When an indoor unit operation mode is Auto or Dehumid,...
  • Page 88 LonWorks Gateway setting (Continued) ● nvoDeviceAlarm(18) 1. Remote control restriction status 2. Filter alert status Description 3. Thermo On/Off status 4. Error alert Status SNVT_state: 16 Unsigned Bitfields SNVT Type Byte Bit9 Bit8 Operation Remark Unlock Flags_1 Level1 nvoUserLockout Lock Byte value Operation...
  • Page 89 ● nvoHeatTempLock(21), nviHeatTempLock(10) Setting/monitoring upper limit temperature Description and function toggle SNVT_switch: Unsigned/signed Short SNVT Type Operation Value State Unlock 16.0 ~ 30.0 Value and operation Lock 16.0 ~ 30.0 Heat: 16.0 °C ~ 30.0 °C ● nvoEnergyConp(23) Description Electric consumption value within the period SNVT_elec_kwh_I: Signed Quad, 4bytes SNVT Type Raw range: 0 ~ 999999...
  • Page 90 LonWorks Gateway setting (Continued) ● nviFilterReset(6) Description Filter alert reset SNVT_switch: Unsigned/singed Short SNVT Type Value State Operation remark Value and operation No Action 100.0 Filter Reset ● nviUserLockout(7), nvoUserLockout(22) Description Remote control restriction SNVT_switch: Unsigned/singed Short SNVT Type Value State Operation remark...
  • Page 91 ● Expansion of nvoDevListDesc desription character value Alphabet or digit Alphabet or digit Alphabet or digit Model information Alphabet or digit Alphabet or digit Alphabet or digit Separator Underbar(_) Alphabet or digit OnOff controller address Alphabet or digit Separator Period(.) [10] Alphabet or digit Interface Module address...
  • Page 92 LonWorks Gateway setting (Continued) Data for DMS System ● nvoDigitalOut(3), nviDigitalOut(1) Description Digital output status on DMS SNVT_switch: Unsigned/singed Short SNVT Type Value State Value and operation 100.0 ● nvoDigitalIn(4) Description Digital Input status on DMS SNVT_switch: Unsigned/singed Short SNVT Type Value State Value and operation...
  • Page 93 ● nvoSystemAlarm(7) Description SIM/PIM Communication Error Code SNVT_count: Unsigned Long, 2 bytes SNVT Type SIM/PIM Communication Error Refer to list of Error code Value and operation ● nviAllOff(2) Description All indoor units turn off Enumeration, emerg_t SNVT Type 0 : EMERG_NORMAL Value and operation 4 : EMERG_SHUTDOWN...
  • Page 94 LonWorks Gateway setting (Continued) Configuration Properties ● Overview This document provides information on all configuration properties defined for LonWorks Gateway device. For the sake of simplicity, although the configuration properties are defined to UFPTSSACSystem functional block, they are shared among the members of UFPTSSACIndoor functional blocks. ●...
  • Page 95 Recommendations If required, set a value greater than the default update rate (currently, 10s). Any smaller value does not yield a change in the update pattern. Associate Values nvoSpaceTemp, nvoSetPoint ● Minimum Temperature Change This configuration property sets the minimum temperature change required before the associated output network variable is updated.
  • Page 96: Pecifications

    Specifications Items Description Exterior Size 240 X 255 X 64.8 mm ( Width X Length X Height ) Weight 1.48 Kg Source DC ADAPTOR Power INPUT Voltage 100-240V 50/60Hz 1.0A OUTPUT Voltage 12V 3A RS-485 5 Channels Ethernet 10/100Mbps 1 Port SD CARD Option (Purchase SD card separately) Inter-...
  • Page 97: Icense

    The software included in this product contains open source software. You may obtain the complete corresponding source code for a period of three years after the last shipment of this product by sending an email to mailto:oss.request@samsung.com. It is also possible to obtain the complete corresponding source code in a physical medium such as a CD-ROM;...
  • Page 98 Memo...