lanpower priority-disconnect

Enables or disables the priority disconnect function on all ports in a specified slot. Priority disconnect is
used by the system software in determining whether an incoming PD will be granted or denied power
when there are too few watts remaining in the PoE power budget for an additional device. For detailed
information on this function, refer to the "Managing Power over Ethernet (PoE)" chapter in the
OmniSwitch 6250 Series Hardware Users Guide.
lanpower slot priority-disconnect {enable | disable}
Syntax Definitions
slot
enable
disable
Defaults
parameter
enable | disable
Platforms Supported
OmniSwitch 6250-Enterprise Models
Usage Guidelines
N/A
Examples
-> lanpower 2 priority-disconnect disable
Release History
Release 6.6.1; command was introduced.
OmniSwitch 6250 CLI Reference Guide
The particular slot on which the priority disconnect function is being
enabled or disabled.
Enables priority disconnect on a specified port. When this function is
enabled and a power budget deficit occurs in which there is inadequate
power for an incoming device, the system software uses priority discon-
nect rules to determine whether an incoming device will be granted or
denied power. For information on priority disconnect rules, refer to the
"Managing Power over Ethernet (PoE)" chapter in the OmniSwitch
6250 Series.
Disables priority disconnect on a specified port. When priority discon-
nect is disabled and there is inadequate power in the budget for an addi-
tional device, power will be denied to any incoming PD, regardless of
its priority status.
default
enable
November 2009