Programming
Operating Instructions 669 PREMIUM - 00.0 - 11/2016
Symbol
Description
Edge Guide
• Gap
Edge stop (if available); value for the distance between
the needle and the material edge.
5.
Exit the submenu using the ESC or
The changed values are stored immediately.
6.
If necessary, create further seam sections or exit Programming
mode using the ESC button.
The program is saved. The machine switches to Automatic
mode and the newly created program is selected.
5.6.5
Adjusting parameters for the selected program
This menu allows the parameters for the current program/seam
program to be changed. This setting affects all seam sections
created in the program.
To adjust the parameters for the selected program:
◄/►
1.
Use
to select the field
2.
Press the OK button.
The submenu opens.
▲/▼
3.
Use
to select the desired parameter.
4.
Press the OK button to activate or deactivate the parameter
▲/▼
or use
to edit the value and confirm the change by press-
ing the OK button.
◄
button
.