Setting: Sewing foot stroke (Stroke)
The sewing foot stroke can be adjusted at different material thick-
nesses by the software.
linear
Stroke
Value range 00 – 09 [mm]
ThickMin
Value range 00.0 – 10.0 [mm]
ThickMax
Value range 00.0 – 10.0 [mm]
2.OnOff ThickMin
Value range 00.0 – 10.0 [mm]
2.On
ThickMin
Value range 00.0 – 10.0 [mm]
Operating Instructions 669 PREMIUM - 00.0 - 11/2016
Programming
Maximum sewing foot stroke
reached at the upper
material thickness limit.
Material thickness at which
the increase in sewing foot
stroke should start.
Material thickness up to
which the increase in
sewing foot stroke should
occur.
Material thickness from
nd
which the 2
sewing foot
stroke height should be
used.
Material thickness from
nd
which the 2
sewing foot
stroke height should be
used.