Duerkopp Adler 669 Premium Operating Instruction page 140

Hide thumbs Also See for 669 Premium:
Table of Contents

Advertisement

138
Code
Possible cause
2371
DA stepper card Z
watchdog (sewing foot lift)
2401
DA stepper card U
reference run timeout
(edge stop)
2430
DA stepper card U not
responding
2431
DA stepper card U Init
fault
3010
U100 V start-up error
3011
U100 V short circuit
3012
2
U100 V (I
3020
U24 V start-up error
3021
U24 V short circuit
3022
2
U24 V (I
T) overload
3030
Motor phase error
Operating Instructions 669 PREMIUM - 00.0 - 11/2016
Remedial action
• Perform software update
• Check class
• Check reference sensor
• Perform software update
• Replace the control
• Perform software update
• Check class
• Disconnect stepper motor
plug; replace control if error is
not corrected
• Disconnect stepper motor
plug; replace control if error is
not corrected
• One or several stepper motors
T) overload
defective
• Disconnect magnetic plug;
replace control if error is not
corrected
• Disconnect magnetic plug;
replace control if error is not
corrected
• One or several magnets
defective
• Replace the control
Troubleshooting