68
Overview of settings modes
The correction of the effects of high speeds can be identified in
various modes and responded to depending on the setting.
This general explanation can be applied to the following specific
parameters.
Setting mode
Description
In the linear setting, the size of the parameter
linear
increases or decreases steadily as the speed
increases. The increase/decrease of the parameter
depends on the limits set for the minimum and
maximum speed.
2.OnOff
If a certain speed is exceeded, the 2
parameter is activated. If the speed then falls below
this level again, it switches to the base value for the
parameter.
2.On
If a certain speed is exceeded, the 2
parameter is activated. If the speed then falls below
this level again, it DOES NOT switch to the base
value for the parameter. Only after finishing the seam
by cutting the thread is the base value for the
parameter set again.