136
Code
Possible cause
1203
Position not reached
1302
Sewing motor voltage
error
1330
No response from sewing
motor
2101
DA stepper card 1
reference run timeout
2105
DA stepper card X
reference run timeout
2121
DA stepper card X
encoder plug (Sub-D,
9-pin) not connected
2122
DA stepper card X
flywheel position not found
2130
DA stepper card X not
responding
2131
DA stepper card X Init
fault
2152
DA stepper card X excess
current
2201
DA stepper card 2
reference run timeout
2205
DA stepper card Y stepper
motor blocked
Operating Instructions 669 PREMIUM - 00.0 - 11/2016
Troubleshooting
Remedial action
• Check and, if necessary,
change controller settings
• Mechanical changes to the
machine (e.g. thread cutting
setting, belt tension)
• Check service stop switch
• Eliminate stiff movement in the
sewing machine
• Replace the encoder
• Replace the sewing motor
• Perform software update
• Replace the control
• Check reference sensor
• Check for stiff movement
• Insert the plug into the control,
use correct connection
• Check stepper motor 1 for stiff
movement
• Perform software update
• Replace the control
• Perform software update
• Check class
• Check for stiff movement
• Check reference sensor
• Check for stiff movement

Advertisement