Duerkopp Adler 669 Premium Operating Instruction page 25

Hide thumbs Also See for 669 Premium:
Table of Contents

Advertisement

Operation
Operating Instructions 669 PREMIUM - 00.0 - 11/2016
To change the needle:
1.
Turn the handwheel until the needle bar (1) reaches the upper
end position.
2.
Loosen the screw (2).
3.
Pull the needle out towards the bottom.
4.
Insert a new needle into the hole in the needle bar (1) until it
reaches the end stop.
Important
Align the needle in such a way that the groove (3) faces the hook (4).
5.
Tighten the screw (2).
Order
Always adjust the clearance between the hook and the needle after
changing to a different needle thickness ( Service Instructions).
Disturbance
An incorrect hook distance can cause the following disturbances:
• Changing to a thinner needle:
• Missing stitches
• Thread damage
• Changing to a thicker needle:
• Damage to the hook tip
• Damage to the needle
23

Advertisement

Table of Contents
loading