UF-5500 / 4500
10.1.9. Service Mode 9 (System Maintenance)
10.1.9.1. Overview
This Service Mode is used to maintain or update the firmware of the machine. Use the following
procedure for System Maintenance.
Step
1
Standby
2
Press "FUNCTION" and then "7".
3
Press "MONITOR" four times, then press "*".
Enter the key operator password (The factory default ID is 00000000.) and press
4
"Set".
5
Press "9".
6
Press "START".
7
Press "SET".
Note:
Now the machine is ready to accept programming firmware code from the PC.
1. Connect the machine to the PC with the USB Cable.
2. Start the Firmware Update Tool using the Wizard.
3. The firmware is copied into the machine.
4.
After the update is completed, the machine reboots itself and returns to standby.
No.
Maintenance Mode
1
FIRMWARE UPDATE
8
SEND RECEIVED FILE
Service Mode 9
Operation or Unit Condition
System Maintenance Table
PC --> Host
Updates the firmware in the machine with the Master Firmware from the PC. After the
firmware is updated, the machine reboots automatically and returns to standby.
Transfers documents from memory to another fax machine during a fatal printer error.