10.1.4.2. Tonal Signal
This Service Mode is used to check the tonal signal output. Signals can be output to the line using the
following procedure.
Step
1
Standby
2
Press "FUNCTION" and then "7".
3
Press "MONITOR" four times, then press "*".
Enter the key operator password (The factory default ID is 00000000.) and press
4
"Set".
5
Press "4".
6
Press "2" and "START".
7
Enter the signal number (1-8) to select the binary signal.
8
Press "CLEAR" to end the signal generation. To select another signal, repeat step 7.
9
Press "STOP" twice to return to standby.
Service Mode 4 - Tonal Signal
Operation or Unit Condition
Tonal Signal Table
Number
1
2
3
4
5
6
7
8
111
Signals
462 Hz
1080 Hz
1100 Hz
1300 Hz
1650 Hz
1850 Hz
2100 Hz
RBT