Code
Mode
Phase
421
RCV
B
422
XMT
B
427
G3
B
RCV
434
XMT or RCV
B
436
G3 RX
C
456
RCV
B
490
RCV
C
494
RCV
C
495
XMT
C
RCV
501
XMT/
B
RCV(V.34)
502
XMT/
B, C, D
RCV(V.34)
503
XMT/
B, C, D
RCV(V.34)
504
XMT/V.34
B
(Polling)
505
XMT/V.34
B
(Polling)
540
XMT ECM
B
541
XMT ECM
D
542
XMT ECM
D
543
XMT ECM
D
544
XMT ECM
D
550
RCV ECM
C
554
RCV ECM
D
580
XMT
B
623
XMT
A
630
XMT or RCV
B
(Polling)
631
XMT
A
Fax Information Codes
Description of Problem
Busy Tone is detected after sending NSF
Signal.
Content of NSF (or DIS) or NSC (or DTC)
was invalid.
DCN received to NSF/CSI/DIS transmitted. The interface is incompatible.
CD (response from Modem) did not turn
OFF within 180 sec. after receiver detected
FLAG signal.
DCN received after transmitting FTT.
Received relay transfer request or confi-
dential document to distribute to an end
receiving station or all confidential mail-
boxes are used.
Sum of error lines exceeded the limit (Func-
tion Parameter No. 70) of 64 lines.
Interval between two EOLs was more than
10 sec. when receiver received message
data.
During reception, CD turned OFF or contin-
ued ON for long time. During communica-
tion, lost loop - current.
Remote unit does not have compatible
Modem.
During reception, CD turned OFF or contin-
ued ON for long time. During communica-
tion, lost loop - current.
CS of modem is not able to turn ON during
training.
Polling is rejected from the remote station.
Polling XMT is rejected.
No response after transmitting 3rd CTC or
DCN received.
No response after transmitting 3rd EOR or
received DCN.
No response to the 3rd RR transmitted or
received DCN.
T5 timer (60 sec.) elapsed without MCF.
Stopped Transmission after EOR Transmis-
sion.
Timer between frames in phase C has
elapsed.
Transmitted ERR after receiving EOR.
Sub-address transmission to a unit that has
their DIS bit 49 (NSF bit 155) OFF.
No original was in the ADF. (Built-in dialer
engaged)
Redial count over.
"STOP" button was pressed during Auto
Dialing.
159
Cause
Remote station disconnected the line.
Wrong number is dialed.
There is an incompatibility.
Remote unit is defective.
MAIN PCB is defective.
Transmitter is defective or incompatible.
Line quality is poor.
Line quality is poor.
MAIN PCB is defective.
Transmitter is defective.
Line quality is poor. (EOL is damaged due to line
noise)
MAIN PCB is defective.
Line is disconnected.
Transmitter is defective.
MAIN PCB is defective.
Line is disconnected.
Transmitter is defective.
MAIN PCB is defective.
MAIN PCB is defective.
Line is disconnected.
No polling original is set.
No polling original is set.
Incompatible interface.
Line is faulty.
MAIN PCB is abnormal.
Remote unit is abnormal.
Remote unit is abnormal.
Line is faulty.
MAIN PCB is abnormal.
Defective remote station.
Line is faulty.
Sub-address transmission to a unit that has no
Sub-address function.
Operator removed the original from the ADF
after dialing was completed.
Original was not set properly in the ADF.
No dial tone detected. Sensor dial tone is not
detected. (destination dependent) Busy tone is
detected. (destination dependent) T1 timer (35
± 5 sec.) elapsed without a signal from the
receiver.
UF-5500 / 4500

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uf-4500

Table of Contents