Xerox DocuColor 2240 Service Manual page 1133

Hide thumbs Also See for DocuColor 2240:
Table of Contents

Advertisement

Chain-
Link
Name
747-483
Low speed 1st Transfer B/W K ECC #7
747-484
Low speed 1st Transfer B/W K ECC #8
747-485
Low speed 1st Transfer B/W K ECC #9
751--xxx Procon NVM List
Chain-Link
Name
751-052
BCR Charge Compensate mode (SW)
751-053
BCR VM temperature & humidity com-
DC2240/1632
pensate mode (SW)
751-132
Bottle Full Counter Print (Max Value)
751-133
Bottle Full (Flag)
751-134
Bottle Not In Position (Flag)
751-135
Print Volume (Counter)
751-136
Bottle Full Counter Dispense (Max
Value)
751-137
Dispense Time Count (4Color Counter) 0
751-138
Bottle Sns Mode (SW)
751-159
BCR Cln Trigger (SW)
751-160
CV Count Total (Counter)
751-161
Drum Cycle Count Total
751-162
Pixel Count Total (Counter)
751-163
BCR Cln CV Count Limit Value (Limiter) 25
751-164
BCR Cln Cycle Count Limit Value (Lim-
iter)
751-165
BCR Cln Pixel Count Limit Value (Lim-
iter)
751-167
BCR Cleaning Count
751-168
CRU Type
751-177
P/R Life Warning (Limiter)
751-178
P/R Life End of Life (Limiter)
751-200
#Y_BCR DC corrected VH value
751-201
#M_BCR DC corrected VH value
751-202
#C_BCR DC corrected VH value
751-203
#K_BCR DC corrected VH value
General Procedures and Information
747--xxx Transfer NVM List, 751--xxx Procon NVM
Table 1 Chain 747
Default
Range
Description
1000
0~2000
Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-031)x 1.0
1000
0~2000
Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-031)x 1.0
1000
0~2000
Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-031)x 1.0
Table 1 Chain 751
Default
Range
Description
0
0~3
Charge Correction. 0=Performs Wear & Environment Correction (Default); 1=Disables Charge Correction;
2=Performs Environment Correction Only; 3=Performs Wear Correction Only
0
0, 1
Vmid Factor Environment Correction. 0=Execute; 1=Disable
900
0~65535
Max Setup Value of EMP Counter Print (1 Count=1print)
0
0~2
0=Empty; 1=Near Full; 2=Full
0
0, 1
Availability of the Toner Waster Bottle (0=Bottle set; 1=No bottle)
0
0~65535
Total count of # of prints (1 Count=1 sheet)
500
0~65535
Max Setup Value of EMP Counter Dispense (1 Count=1 sec.)
0~65535
Total Count of 4 Colors Dispense Time
0
0~2
Specifies the Count method until Bottle Full. 0=Auto(Print&Dispense); 1=Only # of prints; 2=Only Dispense time
3
0~3
Selection SW for Trigger types to operate the BCR Cleaner. 0=CV Count; 1=Drum Cycle Count; 2=Pixel Count;
3=PV Count+ Pixel Count+Drum Cycle
0
0~65535
Each cumulative ERU by Billing Count (1 Count=1pv)
0
0~65535
cumulative Drum Cycle (1 Count=10cycle)
0
0~10000000
cumulative K pixel count. units of 1 step is based on the ICDC control pixel count (1 Count=1dot/1 gradation)
0~255
Threshold in operating BCR Cleaner (Operation after reaching this value) (1 Count=100pv)
50
0~255
Threshold in operating BCR Cleaner (Operation after reaching this value) (1 Count=1k cycle)
15
0~255
Operating threshold for BCR Cleaner. (1 Count=(1dot/1 gradation)/10K)
0
0~1000
Reads the No. of BCR Cleaner Operations. (1 Count=1 time)
0
0~255
80 = XC, ESG, DMO value
1420
0~2000
Warning value of Drum Cartridge (All engine common) (1 bit=0.01µm)
1500
0~2000
End of Life value of Drum Cartridge (All engine common) (1 bit=0.01µm)
620
0~1023
VH Output Value of #Y Engine after Correction (All Speed common) (1 Count=-1.173V)
620
0~1023
VH Output Value of #M Engine after Correction (All Speed common) (1 Count=-1.173V)
620
0~1023
VH Output Value of #C Engine after Correction (All Speed common) (1 Count=-1.173V)
620
0~1023
VH Output Value of #K Engine after Correction (All Speed common) (1 Count=-1.173V)
09/03
6-42
Initial issue
DC 3535/2240/1632, WC M24