Xerox DocuColor 2240 Service Manual page 1149

Hide thumbs Also See for DocuColor 2240:
Table of Contents

Advertisement

Chain-Link
Name
760-050
M-XBI
760-051
C-XBI
760-052
K-XBI
760-053
Y-OLXSO
760-054
M-OLXSO
760-055
C-OLXSO
760-056
K-OLXSO
760-057
Y-OLXBI
760-058
M-OLXBI
760-059
O-OLXBI
General Procedures and Information
760-xxx Regicon NVM List
Table 1 Chain 760
Default
Range
Description
0
0~3
Adjusts fast scan direction write start position by switching the video clock phase from SOS signal.
(DC 2240/1632=1 pixel/bit; DC 3535=1/5 pixel/bit)
0
0~3
Adjusts fast scan direction write start position by switching the video clock phase from SOS signal.
(DC 2240/1632=1 pixel/bit; DC 3535=1/5 pixel/bit)
0
0~3
Adjusts fast scan direction write start position by switching the video clock phase from SOS signal.
(DC 2240/1632=1 pixel/bit; DC 3535=1/5 pixel/bit)
10
0~20
Adjust the writing-start position in FS direction, using Open Loop, with number of video locks from SOS signal,
based on temperature detection results, separately from normal Regi Con cycle
(1 pixel/bit). This NVM is defined by correction amount from the current set value XSO-; the level of correction
amount is four steps from -1 to -4 depending on the temperature. XSO- is overwritten based on the selected
correction amount.
10
0~20
Adjust the writing-start position in FS direction, using Open Loop, with number of video locks from SOS signal,
based on temperature detection results, separately from normal Regi Con cycle
(1 pixel/bit). This NVM is defined by correction amount from the current set value XSO-; the level of correction
amount is four steps from -1 to -4 depending on the temperature. XSO- is overwritten based on the selected
correction amount
10
0~20
Adjust the writing-start position in FS direction, using Open Loop, with number of video locks from SOS signal,
based on temperature detection results, separately from normal Regi Con cycle
(1 pixel/bit). This NVM is defined by correction amount from the current set value XSO-; the level of correction
amount is four steps from -1 to -4 depending on the temperature. XSO- is overwritten based on the selected
correction amount
10
0~20
Adjust the writing-start position in FS direction, using Open Loop, with number of video locks from SOS signal,
based on temperature detection results, separately from normal Regi Con cycle
(1 pixel/bit). This NVM is defined by correction amount from the current set value XSO-; the level of correction
amount is four steps from -1 to -4 depending on the temperature. XSO- is overwritten based on the selected
correction amount
0
0~3
Adjust writing-start position in FS direction in Open Loop, by switching video lock phase from SOS signal, based
on temperature detection results, separately from normal Regi Con cycle
(DC 2240/1632=1 pixel/bit; DC 3535=1/5 pixel/bit).
This NVM is defined with the correction amount from the current set values XBI-, XSO-; its level is 5 steps from
-1 to -5 depending on the temperature. XBI- and XSO- are overwritten based on the selected correction
amount.
0
0~3
Adjust writing-start position in FS direction in Open Loop, by switching video lock phase from SOS signal, based
on temperature detection results, separately from normal Regi Con cycle
(DC 2240/1632=1 pixel/bit; DC 3535=1/5 pixel/bit).
This NVM is defined with the correction amount from the current set values XBI-, XSO-; its level is 5 steps from
-1 to -5 depending on the temperature. XBI- and XSO- are overwritten based on the selected correction
amount.
0
0~3
Adjust writing-start position in FS direction in Open Loop, by switching video lock phase from SOS signal, based
on temperature detection results, separately from normal Regi Con cycle
(DC 2240/1632=1 pixel/bit; DC 3535=1/5 pixel/bit).
This NVM is defined with the correction amount from the current set values XBI-, XSO-; its level is 5 steps from
-1 to -5 depending on the temperature. XBI- and XSO- are overwritten based on the selected correction
amount.
09/03