FLIR Client 12 for PC / Mac
3. Use the dropdown next to Overwrite to select the overwrite mode.
• Auto: Deletes the oldest saved footage when the hard drive is full.
• 1–90 Days: Keeps footage for as long as specified before overwriting. Ensure your
hard drive is large enough to retain recordings for as long as you have specified.
• Off: No footage will be overwritten.
CAUTION
If you turn off overwrite and your hard drive fills up with footage, the system will stop recording.
4. Click Save.
13.6.18 Configuring PTZ Cameras
Configure PTZ cameras to be used by the system. This is for initial setup purposes only.
For using already configured PTZ cameras using FLIR Client 12, see 13.4.3 PTZ Controls,
page 96.
NOTE
For the correct values to enter into the fields below, consult your PTZ camera instruction manual.
To configure PTZ cameras:
1. Click Remote Setting in the top-right corner of the window.
2. Under Device, click PTZ to open the PTZ tab.
3. Use the dropdown next to Channel to select the channel your PTZ camera is con-
nected to.
4. Select the PTZ camera's protocol from the dropdown next to Protocol.
5. Select the PTZ camera's baud rate from the dropdown next to Baudrate.
6. Select the PTZ camera's data bit from the dropdown next to DataBit.
7. Select the PTZ camera's stop bit from the dropdown next to StopBit.
8. Select the PTZ camera's parity from the dropdown next to Parity.
9. Click the switch next to Cruise to enable (
functionality.
#LX400086; r. 1.0/39246/39246; en-US
) or disable (
) PTZ cruise