Fnc156 - Zrn / Zero Return - Mitsubishi FX3G Series Programming Manual

Programmable controllers
Hide thumbs Also See for FX3G Series:
Table of Contents

Advertisement

FX
/FX
/FX
/FX
3G
3U
3GC
3UC
Programming Manual - Basic & Applied Instruction Edition
20.5
FNC156 – ZRN / Zero Return
Outline
This instruction executes a zero return, and aligns the mechanical position with a present value register inside the
PLC.
When the dog search function is required, use DSZR (FNC150) instruction.
1. Instruction format
FNC 156
D
ZRN
2. Set data
Operand type
S
1
S
2
S
3
D
*1.
Setting range: 10 to 32767 Hz for 16-bit operation
3. Applicable devices
Bit Devices
Oper-
System User
and
Type
X Y M T C S D .b KnX KnY KnM KnS T
S
1
S
2
S
3
D
2
1 : "D .b" is available only in FX
2 : Specify Y000, Y001 or Y002
from a high-speed output special adapter
*1.
Y002 is not available in FX
*2.
High-speed output special adapters can be connected only to FX
*3.
To use Y002 and Y003 with a high-speed output special adapter, connected a second high-speed output
special adapter.
Points
• When using a relay output type or triac output type FX
required.
• Outputs of special high-speed output adapters work as differential line drivers.
3 : This function is supported only in FX
Series
→ For explanation of the instruction, refer to the Positioning Control Edition manual.
Mnemonic
16-bit Instruction
9 steps
ZRN
*1
Initial zero return speed
Creep speed [10 to 32767 Hz]
Device number for near-point signal (dog)
Device number (Y) from which pulses are to be output
Following range for 32-bit operation
Pulse output destination
FX
PLC
3U
FX
/FX
/FX
/FX
PLCs Main unit (transistor output)
3G
3U
3GC
3UC
Digit Specification
1
and FX
3U
3UC
*1
transistor output from the main unit, or specify Y000, Y001, Y002
PLC (14-point and 24-point type) and FX
3G
/FX
3U
20 Positioning Control – FNC150 to FNC159
→ For cautions on using special high-speed output adapters,
refer to the Positioning Control Edition manual.
Operation Condition
32-bit Instruction
Continuous
17 steps
Operation
Description
Special high-speed output adapter
Word Devices
Special
System User
Unit
C D R U \G
V
3
3
PLCs. However, index modifiers (V and Z) are not available.
*2
.
PLC, a special high-speed output adapter is
3U
PLCs.
3UC
20.5 FNC156 – ZRN / Zero Return
Mnemonic
Operation Condition
Continuous
DZRN
Operation
Data type
16- or 32-bit binary
Bit
Setting range
10 to 200,000 (Hz)
10 to 100,000 (Hz)
Others
Con-
Real
Charac-
Index
stant
Number
ter String
Z Modify K H
E
" "
*3
PLC.
3GC
PLC.
3U
11
12
13
14
15
16
Pointer
17
P
18
*3
or Y003
19
20
547