2. 32-bit operation (DPLSY)
A pulse train at the frequency [
D
.
Command
input
FNC 57
DPLSY
• Specify the frequency in [
- When special high-speed output adapters are used
Allowable setting range: 1 to 200,000 (Hz)
- When the FX
Allowable setting range: 1 to 100,000 (Hz)
• Specify the generated pulse quantity in [
Allowable setting range: 1 to 2,147,483,647 (PLS)
• Specify the output (Y) number from which pulses are output in
Allowable setting range: Y000, Y001
→ For the method to output pulses without any limitation, refer to the program example later.
Related devices
1. Instruction execution complete flag
The instruction execution complete flag M8029 used for PLSY instruction can be used also for other instructions.
When using other instructions, setting the M8029 flag to ON or OFF, or using two or more PLSY instructions, make
sure to use each M8029 flag just after an instruction to be monitored.
Device
Instruction execution com-
M8029
Command
input 1
FNC 57
PLSY
M8029
Command
input 2
FNC 57
DPLSY
M8029
Series
S
+1,
S
1
1
S
S
D
1
2
S
+1,
S
].
1
1
/FX
/FX
/FX
PLCs main unit is used
3G
3U
3GC
3UC
S
2
→ For the instruction execution complete flag use method, refer to Subsection 6.5.2.
Name
ON: Generation of specified number of pulses is completed.
OFF: Generation of pulses is paused before the specified number of pulses is reached or the
plete
continuous pulse generation operation is stopped.
K1000
K0
Y000
K1000
K0
Y000
13 High-Speed Processing – FNC 50 to FNC 59
] is output by the quantity [
[
+ 1,
S
2
D
[
+1,
S
].
2
D
.
Description
Command
input 1
FNC 57
PLSY
Command
input 2
FNC 57
DPLSY
Command
input 1
M8029
Command
M8029
input 2
13.8 FNC 57 – PLSY / Pulse Y Output
S
+1,
S
] from the output (Y)
2
2
Pulse quantity
]
S
2
S
Frequency
]
S
+ 1,
1
1
K1000
K0
Y000
K1000
K0
Y001
Changes by DPSLY
instruction corresponding to
the command input 2.
11
12
13
14
15
16
17
18
19
20
369